PURPOSE: We report our experience with endoluminal stent placement after percutaneous transluminal angioplasty for the treatment of post-transplant renal artery stenosis. MATERIALS AND METHODS: From October 1992 to September 1996, 8 stents were successfully implanted in 7 patients affected by resistant transplant renal artery stenosis. All transplanted kidneys were procured from cadaver donors. The patients were routinely evaluated with duplex sonography and the median interval between transplantation and stenosis detection was 7.4 months (range 0.5 to 17). When serious renal stenosis was diagnosed (greater than 50%), selected angiography and percutaneous transluminal angioplasty were performed. In 8 cases (7 patients) an endoluminal metallic Palmaz stent was placed in the site of the restenosis. One patient received 2 stents repeatedly positioned in different stenosis sites. RESULTS: No major complications occurred. Clinical outcome was positive in 5 patients (71.4%) and Stenosis recurred in 2 (28.5%) (less than 50% and less than 35%, respectively). Median followup after stent placement was 14.8 months (range 1 to 37). CONCLUSIONS: Percutaneous endoluminal stent procedures after resistant transplant renal artery stenosis or for ex novo treatment for severe anastomotic stenoses appears to be promising. Longer followup periods are necessary for true evaluation of this procedure.

Endoluminal stent placement after percutaneous transluminal angioplasty in the treatment of post-transplant renal artery stenosis / Nicita G;Villari D;Marzocco M;Li Marzi V;Trippitelli A;Santoro G. - In: THE JOURNAL OF UROLOGY. - ISSN 0022-5347. - ELETTRONICO. - 159:(1998), pp. 34-37. [10.1016/S0022-5347(01)64004-7]

Endoluminal stent placement after percutaneous transluminal angioplasty in the treatment of post-transplant renal artery stenosis

VILLARI, DONATA;LI MARZI, VINCENZO;
1998

Abstract

PURPOSE: We report our experience with endoluminal stent placement after percutaneous transluminal angioplasty for the treatment of post-transplant renal artery stenosis. MATERIALS AND METHODS: From October 1992 to September 1996, 8 stents were successfully implanted in 7 patients affected by resistant transplant renal artery stenosis. All transplanted kidneys were procured from cadaver donors. The patients were routinely evaluated with duplex sonography and the median interval between transplantation and stenosis detection was 7.4 months (range 0.5 to 17). When serious renal stenosis was diagnosed (greater than 50%), selected angiography and percutaneous transluminal angioplasty were performed. In 8 cases (7 patients) an endoluminal metallic Palmaz stent was placed in the site of the restenosis. One patient received 2 stents repeatedly positioned in different stenosis sites. RESULTS: No major complications occurred. Clinical outcome was positive in 5 patients (71.4%) and Stenosis recurred in 2 (28.5%) (less than 50% and less than 35%, respectively). Median followup after stent placement was 14.8 months (range 1 to 37). CONCLUSIONS: Percutaneous endoluminal stent procedures after resistant transplant renal artery stenosis or for ex novo treatment for severe anastomotic stenoses appears to be promising. Longer followup periods are necessary for true evaluation of this procedure.
1998
159
34
37
Goal 4: Quality education
Nicita G;Villari D;Marzocco M;Li Marzi V;Trippitelli A;Santoro G
File in questo prodotto:
File Dimensione Formato  
endoluminal stent 1998 JoU .pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 873.43 kB
Formato Adobe PDF
873.43 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/651524
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact