INTRODUCTION: We investigated the accuracy of endorectal coil Magnetic Resonance Imaging (MRI) and Fast Spin Echo (FSE) technique in staging prostate cancer. MATERIAL AND METHODS: MRI was performed in 70 patients with biopsy proved prostatic cancer. A total of 33 patients subsequently underwent radical prostatectomy. T2-weighted FSE sequences (TR 3400-4100, TE 120, Echo train length 13) were acquired in all patients. Axial, sagittal and coronal 4-5 mm images were obtained with 13-14 cm field of view and 256 x 256 matrix. Additional T1-weighted spin echo images were acquired in 9 patients. Lesion staging on MR images was performed according to the American Urological System. MR data were compared with the pathologic findings of whole-mount sections of the surgical specimens. RESULTS: Overall accuracy for endorectal coil MR imaging was 60%; ten cases were underestimated and 3 cases were overestimated. The sensitivity and the specificity of endorectal coil MRI in diagnosing capsular penetration were 77% and 81%, respectively. Seminal vesicle invasion was detected with 87% sensitivity and 96% specificity. CONCLUSIONS: Endorectal coil MRI provides a more accurate preoperative local staging.
Magnetic resonance with an endorectal coil and a fast spin echo sequence in the staging of prostatic carcinoma. The correlation with histopathological data / Masi A;Olmastroni M;Marin E;Consalvo M;Lascialfari L;Ricupero L;Nicita G;Villari D;Amorosi A;Villari N. - In: LA RADIOLOGIA MEDICA. - ISSN 0033-8362. - ELETTRONICO. - 94:(1997), pp. 496-502.
Magnetic resonance with an endorectal coil and a fast spin echo sequence in the staging of prostatic carcinoma. The correlation with histopathological data.
VILLARI, DONATA;
1997
Abstract
INTRODUCTION: We investigated the accuracy of endorectal coil Magnetic Resonance Imaging (MRI) and Fast Spin Echo (FSE) technique in staging prostate cancer. MATERIAL AND METHODS: MRI was performed in 70 patients with biopsy proved prostatic cancer. A total of 33 patients subsequently underwent radical prostatectomy. T2-weighted FSE sequences (TR 3400-4100, TE 120, Echo train length 13) were acquired in all patients. Axial, sagittal and coronal 4-5 mm images were obtained with 13-14 cm field of view and 256 x 256 matrix. Additional T1-weighted spin echo images were acquired in 9 patients. Lesion staging on MR images was performed according to the American Urological System. MR data were compared with the pathologic findings of whole-mount sections of the surgical specimens. RESULTS: Overall accuracy for endorectal coil MR imaging was 60%; ten cases were underestimated and 3 cases were overestimated. The sensitivity and the specificity of endorectal coil MRI in diagnosing capsular penetration were 77% and 81%, respectively. Seminal vesicle invasion was detected with 87% sensitivity and 96% specificity. CONCLUSIONS: Endorectal coil MRI provides a more accurate preoperative local staging.I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.