This work concerns the development of an experimental set-up for assessing the influence of fluxes on Partial Discharge (PD) onset in High Voltage (HV) devices soldered on Printed Circuit Boards (PCBs). In particular, the work considered the effects of three types of fluxes chosen in agreement with the directions of the Materials and Processes Division at ESA/ESTEC. Contaminated samples are formed by a standard FR-4 PCB board with a pair of copper electrodes and a protocol of contamination has been applied for all samples. The measuring system is placed inside a shielded chamber and provides measurements of Corona Inception Voltage (CIV), Corona Extinction Voltage (CEV) and PD amplitudes collected in a vacuum chamber with controlled temperature fixture. The results shows that flux Alpha 850-33 has the mean CIV smaller than other types of fluxes and the same results is observed for the mean CEV. Also the PD amplitudes are greater for samples contaminated with flux Alpha 850-33 than the other two types and similar in value for samples without flux.
Experimental results on the influence of fluxes on partial discharge onset in PCB solder joints / Bulletti, Andrea; Capineri, Lorenzo; Materassi, M.. - STAMPA. - (2003), pp. 573-578. (Intervento presentato al convegno Proceedings of ‘Materials in a Space Environment’ tenutosi a Noordwijk, The Netherlands nel 16 - 20 June 2003).
Experimental results on the influence of fluxes on partial discharge onset in PCB solder joints
BULLETTI, ANDREA;CAPINERI, LORENZO;
2003
Abstract
This work concerns the development of an experimental set-up for assessing the influence of fluxes on Partial Discharge (PD) onset in High Voltage (HV) devices soldered on Printed Circuit Boards (PCBs). In particular, the work considered the effects of three types of fluxes chosen in agreement with the directions of the Materials and Processes Division at ESA/ESTEC. Contaminated samples are formed by a standard FR-4 PCB board with a pair of copper electrodes and a protocol of contamination has been applied for all samples. The measuring system is placed inside a shielded chamber and provides measurements of Corona Inception Voltage (CIV), Corona Extinction Voltage (CEV) and PD amplitudes collected in a vacuum chamber with controlled temperature fixture. The results shows that flux Alpha 850-33 has the mean CIV smaller than other types of fluxes and the same results is observed for the mean CEV. Also the PD amplitudes are greater for samples contaminated with flux Alpha 850-33 than the other two types and similar in value for samples without flux.File | Dimensione | Formato | |
---|---|---|---|
Capineri_Bulletti_Mat_Space_Symp_ESA2003.pdf
Accesso chiuso
Tipologia:
Versione finale referata (Postprint, Accepted manuscript)
Licenza:
Tutti i diritti riservati
Dimensione
443.43 kB
Formato
Adobe PDF
|
443.43 kB | Adobe PDF | Richiedi una copia |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.