The advantages of ferroelectric polymer technology when building hemicylindrical ultrasonic transducers for airborne applications, have been already broadly investigated by the authors. The theory, experimentally confirmed, showed that the resonance frequency is inversely proportional to the bending radius. Based on this unique property a double frequency array sensor was built up in order to have a large bandwidth otherwise obtainable with more sophisticated and expensive fabrication technologies. In this work, the design is described of two interlaced series of transducers with the resonance frequency equal to 60 kHz and 86 kHz respectively. Experimental characteristics of the array elements have been derived and an imaging system based on the reflection tomography technique was gathered and tested in a laboratory environment. The overall system performance is reported via the point spread function image evaluated by the response to a thin steel wire. The spatial resolution is about 3 mm along both the lateral and axial direction

Array of PVDF sensors for ultrasonic imaging in air / Capineri, Lorenzo; Fiorillo, A. S.; Masotti, Leonardo; Rocchi, S.. - ELETTRONICO. - (1994), pp. 487-490. (Intervento presentato al convegno IEEE Ultrasonics Symposium tenutosi a Cannes, France nel 31 Oct.-3 Nov. 1994) [10.1109/ULTSYM.1994.401634].

Array of PVDF sensors for ultrasonic imaging in air

CAPINERI, LORENZO
Conceptualization
;
MASOTTI, LEONARDO;
1994

Abstract

The advantages of ferroelectric polymer technology when building hemicylindrical ultrasonic transducers for airborne applications, have been already broadly investigated by the authors. The theory, experimentally confirmed, showed that the resonance frequency is inversely proportional to the bending radius. Based on this unique property a double frequency array sensor was built up in order to have a large bandwidth otherwise obtainable with more sophisticated and expensive fabrication technologies. In this work, the design is described of two interlaced series of transducers with the resonance frequency equal to 60 kHz and 86 kHz respectively. Experimental characteristics of the array elements have been derived and an imaging system based on the reflection tomography technique was gathered and tested in a laboratory environment. The overall system performance is reported via the point spread function image evaluated by the response to a thin steel wire. The spatial resolution is about 3 mm along both the lateral and axial direction
1994
Proceedings of IEEE Ultrasonics Symposium ULTSYM-94
IEEE Ultrasonics Symposium
Cannes, France
31 Oct.-3 Nov. 1994
Capineri, Lorenzo; Fiorillo, A. S.; Masotti, Leonardo; Rocchi, S.
File in questo prodotto:
File Dimensione Formato  
UFFC_SYMP_1995.pdf

accesso aperto

Tipologia: Versione finale referata (Postprint, Accepted manuscript)
Licenza: Open Access
Dimensione 71.37 kB
Formato Adobe PDF
71.37 kB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/673560
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact