OBJECTIVE: To define normal values for respiratory resistance (R(rs)) and reactance (X(rs)) and bronchodilator response (BDR) in a population of healthy Italian preschool children using a commercially available forced oscillation device. METHODS: R(rs) and X(rs) were measured in kindergartens in Viterbo, Italy. Regression analysis was performed taking into account height, weight, age, gender, and reference equations calculated. The coefficient of repeatability (CR) between two tests performed 15 min apart was calculated in a subset of children. BDR was assessed by repeating the measurements 15 min after the administration of 200 µg of inhaled salbutamol and calculated as an absolute change in R(rs) and X(rs) at 8 Hz, as a percent change in baseline, and as a change in Z-score calculated from the reference equations. RESULTS: Lung function was attempted in 175 healthy children and successful in 163 (81 male, median age 4.8, range 2.9-6.1 years). R(rs) and X(rs) at 6, 8, and 10 Hz were related to height but not other variables. The CR was 1.53 hPa s L(-1) for R(rs8) and 0.91 hPa s L(-1) for X(rs8). The 5th percentile for absolute R(rs8) BDR was -3.16 hPa s L(-1), whereas the 95th percentile for absolute X(rs8) BDR was 2.25 hPa s L(-1). These cut-off values corresponded to a change in the Z-score of -1.88 and 2.48, respectively. CONCLUSIONS: We have established reference equations for R(rs) and X(rs) in healthy Italian preschool children using forced oscillations. We recommend a change in Z-score of -1.88 for R(rs8) and 2.48 for X(rs8) as cut-off values for a positive BDR.
Respiratory impedance and bronchodilator response in healthy Italian preschoolchildren / Calogero C; Parri N; Baccini A; Cuomo B; Palumbo M; Novembre E; Morello P; Azzari C; de Martino M; Sly PD; Lombardi E.. - In: PEDIATRIC PULMONOLOGY. - ISSN 8755-6863. - STAMPA. - 45(11):(2010), pp. 1086-1094. [10.1002/ppul.21292]
Respiratory impedance and bronchodilator response in healthy Italian preschoolchildren.
NOVEMBRE, ELIO MASSIMO;AZZARI, CHIARA;DE MARTINO, MAURIZIO;
2010
Abstract
OBJECTIVE: To define normal values for respiratory resistance (R(rs)) and reactance (X(rs)) and bronchodilator response (BDR) in a population of healthy Italian preschool children using a commercially available forced oscillation device. METHODS: R(rs) and X(rs) were measured in kindergartens in Viterbo, Italy. Regression analysis was performed taking into account height, weight, age, gender, and reference equations calculated. The coefficient of repeatability (CR) between two tests performed 15 min apart was calculated in a subset of children. BDR was assessed by repeating the measurements 15 min after the administration of 200 µg of inhaled salbutamol and calculated as an absolute change in R(rs) and X(rs) at 8 Hz, as a percent change in baseline, and as a change in Z-score calculated from the reference equations. RESULTS: Lung function was attempted in 175 healthy children and successful in 163 (81 male, median age 4.8, range 2.9-6.1 years). R(rs) and X(rs) at 6, 8, and 10 Hz were related to height but not other variables. The CR was 1.53 hPa s L(-1) for R(rs8) and 0.91 hPa s L(-1) for X(rs8). The 5th percentile for absolute R(rs8) BDR was -3.16 hPa s L(-1), whereas the 95th percentile for absolute X(rs8) BDR was 2.25 hPa s L(-1). These cut-off values corresponded to a change in the Z-score of -1.88 and 2.48, respectively. CONCLUSIONS: We have established reference equations for R(rs) and X(rs) in healthy Italian preschool children using forced oscillations. We recommend a change in Z-score of -1.88 for R(rs8) and 2.48 for X(rs8) as cut-off values for a positive BDR.File | Dimensione | Formato | |
---|---|---|---|
2010 pediatr pumonol.pdf
accesso aperto
Tipologia:
Altro
Licenza:
Open Access
Dimensione
247.47 kB
Formato
Adobe PDF
|
247.47 kB | Adobe PDF |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.