We report on our progress toward the realization of an optical frequency standard referenced to strontium intercombination lines. While first frequency measurement of the weakly allowed 1S 0- 3P 1 transition was done with saturation spectroscopy on a thermal beam, we are preparing the experimental setup for high resolution spectroscopy on ultracold atoms of the doubly forbidden 1S 0- 3P 0 line. Our current setup allows the capture more than 10 7 atoms at 1 μK in 500 ms in two stages of magneto-optical trapping. We also demonstrated the dipole trapping of ultracold strontium isotopes for accurate spectroscopy and collisional measurements. A semiconductor laser source at 698 nm has already been locked to a pre-stabilization cavity obtaining a fast linewidth of less than 1 kHz. Second stage stabilization of the clock laser to ultra-high finesse cavity is in development. Recent measurement of elastic and inelastic cross-sections of the two most abundant 88Sr and 86Sr isotopes are also presented.
Optical frequency standard with ultra-cold strontium atoms / N. Poli; R. E. Drullinger; M. G. Tarallo; G. M. Tino; M. Prevedelli. - STAMPA. - (2006), pp. 333-337. (Intervento presentato al convegno 20th European Time and Frequency Symposium (EFTF2006) tenutosi a Braunschweig (D) nel 27-30 March (2006)).
Optical frequency standard with ultra-cold strontium atoms
POLI, NICOLA;TINO, GUGLIELMO MARIA;
2006
Abstract
We report on our progress toward the realization of an optical frequency standard referenced to strontium intercombination lines. While first frequency measurement of the weakly allowed 1S 0- 3P 1 transition was done with saturation spectroscopy on a thermal beam, we are preparing the experimental setup for high resolution spectroscopy on ultracold atoms of the doubly forbidden 1S 0- 3P 0 line. Our current setup allows the capture more than 10 7 atoms at 1 μK in 500 ms in two stages of magneto-optical trapping. We also demonstrated the dipole trapping of ultracold strontium isotopes for accurate spectroscopy and collisional measurements. A semiconductor laser source at 698 nm has already been locked to a pre-stabilization cavity obtaining a fast linewidth of less than 1 kHz. Second stage stabilization of the clock laser to ultra-high finesse cavity is in development. Recent measurement of elastic and inelastic cross-sections of the two most abundant 88Sr and 86Sr isotopes are also presented.File | Dimensione | Formato | |
---|---|---|---|
PoliEFTF2006.pdf
accesso aperto
Descrizione: Articolo
Tipologia:
Pdf editoriale (Version of record)
Licenza:
Open Access
Dimensione
451.11 kB
Formato
Adobe PDF
|
451.11 kB | Adobe PDF |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.