In this paper, two simple and sensitive approaches for CA 125 detection are presented by using antibody immobilized on poly-anthranilic acid modified graphite screen-printed electrodes. The first proposed approach is a labelfree impedimetric immunosensor. The immunoassay is based on poly-anthranilic acid (PAA) modified graphite screen-printed electrodes with subsequent covalently monoclonal antibody anti-CA 125 immobilization. The modified screen-printed electrodes are used to capture the protein from the sample solutions. A curve calibration by electrochemical impedance spectroscopy (EIS) was obtained. The second approach is based on a sandwich format. The monoclonal anti-CA 125 antibodies immobilized on poly-anthranilic acid modified graphite screen-printed electrodes is used to capture the protein from the sample solution. The sandwich assay is then performed by adding secondary anti-CA 125 antibodies labeled with gold nanoparticles (AuNPs). The antibody-AuNPs captured onto immunosensor surface induced the silver deposition from a silver enhancer solution. The deposited AgNPs could be measured by anodic stripping analysis (ASV) in acid solution. A curve calibration by ASV was obtained. The experimental conditions were examined and were optimized using electrochemical impedance spectroscopy. The performance of both immunosensors in terms of sensitivity, reproducibility and selectivity were studied.

CA125 Immunosensor Based on Poly-Anthranilic Acid Modified Screen-Printed Electrodes / Zahra Taleat; Andrea Ravalli; Mohammad Mazloum-Ardakani; Giovanna Marrazza. - In: ELECTROANALYSIS. - ISSN 1040-0397. - STAMPA. - 24:(2013), pp. 269-277. [10.1002/elan.201200425]

CA125 Immunosensor Based on Poly-Anthranilic Acid Modified Screen-Printed Electrodes

RAVALLI, ANDREA;MARRAZZA, GIOVANNA
2013

Abstract

In this paper, two simple and sensitive approaches for CA 125 detection are presented by using antibody immobilized on poly-anthranilic acid modified graphite screen-printed electrodes. The first proposed approach is a labelfree impedimetric immunosensor. The immunoassay is based on poly-anthranilic acid (PAA) modified graphite screen-printed electrodes with subsequent covalently monoclonal antibody anti-CA 125 immobilization. The modified screen-printed electrodes are used to capture the protein from the sample solutions. A curve calibration by electrochemical impedance spectroscopy (EIS) was obtained. The second approach is based on a sandwich format. The monoclonal anti-CA 125 antibodies immobilized on poly-anthranilic acid modified graphite screen-printed electrodes is used to capture the protein from the sample solution. The sandwich assay is then performed by adding secondary anti-CA 125 antibodies labeled with gold nanoparticles (AuNPs). The antibody-AuNPs captured onto immunosensor surface induced the silver deposition from a silver enhancer solution. The deposited AgNPs could be measured by anodic stripping analysis (ASV) in acid solution. A curve calibration by ASV was obtained. The experimental conditions were examined and were optimized using electrochemical impedance spectroscopy. The performance of both immunosensors in terms of sensitivity, reproducibility and selectivity were studied.
2013
24
269
277
Zahra Taleat; Andrea Ravalli; Mohammad Mazloum-Ardakani; Giovanna Marrazza
File in questo prodotto:
File Dimensione Formato  
Electroanalysis_2012.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 525.49 kB
Formato Adobe PDF
525.49 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/777646
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 65
  • ???jsp.display-item.citation.isi??? 63
social impact