Proton Computed Tomography (pCT) is an imaging method under investigation with the aim to improve the accuracy of treatment planning and patient positioning in hadron therapy. A pCT system should be capable to measure tissue electron density with an accuracy better than 1% and with a spatial resolution better than 1mm. A first apparatus based on a silicon tracker and a YAG:Ce crystal calorimeter, with a 5x5 cm2 active area, has been already developed by the authors in the framework of the PRIMA (Proton Imaging) collaboration and tested with proton beams with promising results. A second prototype with larger area (5x20 cm2) and improved data acquisition system is being designed. The details about this new prototype will be presented in this work.
Development of a Proton Computed Tomography System for Pre-Clinical Tests / C. Civinini; M. Brianzi; M. Bruzzi; M. Bucciolini; M. Carpinelli; G. A. P. Cirrone; G. Cuttone; D. Lo Presti; S. Pallotta; C. Pugliatti; N. Randazzo; F. Romano; M. Scaringella; V. Sipala; C. Stancampiano; C. Talamonti; M. Tesi; E. Vanzi; M. Zani. - ELETTRONICO. - N14-177:(2013), pp. 1279-1283. (Intervento presentato al convegno 2012 IEEE Nuclear Science Symposium and medical imaging Conference record tenutosi a Anaheim California USA nel october 29- November 3 2012).
Development of a Proton Computed Tomography System for Pre-Clinical Tests
BRUZZI, MARA;BUCCIOLINI, MARTA;PALLOTTA, STEFANIA;SCARINGELLA, MONICA;TALAMONTI, CINZIA;VANZI, ELEONORA;ZANI, MARGHERITA
2013
Abstract
Proton Computed Tomography (pCT) is an imaging method under investigation with the aim to improve the accuracy of treatment planning and patient positioning in hadron therapy. A pCT system should be capable to measure tissue electron density with an accuracy better than 1% and with a spatial resolution better than 1mm. A first apparatus based on a silicon tracker and a YAG:Ce crystal calorimeter, with a 5x5 cm2 active area, has been already developed by the authors in the framework of the PRIMA (Proton Imaging) collaboration and tested with proton beams with promising results. A second prototype with larger area (5x20 cm2) and improved data acquisition system is being designed. The details about this new prototype will be presented in this work.File | Dimensione | Formato | |
---|---|---|---|
N14-177.pdf
accesso aperto
Tipologia:
Altro
Licenza:
Open Access
Dimensione
525.15 kB
Formato
Adobe PDF
|
525.15 kB | Adobe PDF |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.