An experimental investigation on large scaled models of gas turbine ribbed circular cooling channels was performed in order to measure heat transfer coefficients and friction factors. Heat transfer coefficients maps were evaluated using narrow band thermo-chromic liquid crystals within a transient technique. Friction factors were evaluated measuring the pressure drop along the ducts with piezoresistive pressure sensors in cold tests. The streamwise averaged Nusselt numbers were fitted in order to highlight the Reynolds number dependence and a comparison with smooth ducts was performed in terms of heat transfer and friction enhancement. Finally a comparison with some published correlations for square and rectangular ducts was done and correction factors were evaluated in order to obtain heat transfer coefficients and friction factors for the present circular ribbed ducts.

Heat transfer and friction in circular ducts with shaped ribs / Leonardo Bonanni; Riccardo Da Soghe; Bruno Facchini; Mirko Micio; Marco Pievaroli; Lorenzo Tarchi; Luca Abba; Massimiliano Maritano. - ELETTRONICO. - (2013), pp. 0-0. (Intervento presentato al convegno 10th European Turbomachinery Conference tenutosi a Lappeenranta - FINLAND nel 15-19 Aprile 2013).

Heat transfer and friction in circular ducts with shaped ribs

BONANNI, LEONARDO;FACCHINI, BRUNO;MICIO, MIRKO;PIEVAROLI, MARCO;TARCHI, LORENZO;
2013

Abstract

An experimental investigation on large scaled models of gas turbine ribbed circular cooling channels was performed in order to measure heat transfer coefficients and friction factors. Heat transfer coefficients maps were evaluated using narrow band thermo-chromic liquid crystals within a transient technique. Friction factors were evaluated measuring the pressure drop along the ducts with piezoresistive pressure sensors in cold tests. The streamwise averaged Nusselt numbers were fitted in order to highlight the Reynolds number dependence and a comparison with smooth ducts was performed in terms of heat transfer and friction enhancement. Finally a comparison with some published correlations for square and rectangular ducts was done and correction factors were evaluated in order to obtain heat transfer coefficients and friction factors for the present circular ribbed ducts.
2013
European Turbomachinery Conference
10th European Turbomachinery Conference
Lappeenranta - FINLAND
15-19 Aprile 2013
Leonardo Bonanni; Riccardo Da Soghe; Bruno Facchini; Mirko Micio; Marco Pievaroli; Lorenzo Tarchi; Luca Abba; Massimiliano Maritano
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/795077
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact