From the clinical point of view, primary implant stability is a fundamental requirement. The aim of the present work was to investigate the primary stability of two types of dental implants, with truncated cone (TC) and cylindrical (CL) geometry, by evaluating their performance by means of pull-out tests. Moreover, several samples were tested by varying surgical preparation method as well as the material where the implant was housed in order to assess whether primary stability could be affected by these factors. A critical load which corresponds to a displacement of 0.2. mm in pull-out test was chosen as indicator of the implant primary stability. CL implants had the advantage of requiring lower torques during the installation phase, and thus, applying less local stresses on the bone. Among the housing preparation methods investigated in the present study, the housings realized by using two mill cutters of different diameters for different depths implied higher primary stability for TC implant.
Analysis and comparison of clutch techniques of two dental implants / Giovanni Zonfrillo; Sara Matteoli; Andrea Ciabattini; Maurizio Dolfi; Lorenzo Lorenzini; Andrea Corvi. - In: JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS. - ISSN 1751-6161. - ELETTRONICO. - 34:(2014), pp. 1-7. [10.1016/j.jmbbm.2014.01.017]
Analysis and comparison of clutch techniques of two dental implants
ZONFRILLO, GIOVANNI;MATTEOLI, SARA;CORVI, ANDREA
2014
Abstract
From the clinical point of view, primary implant stability is a fundamental requirement. The aim of the present work was to investigate the primary stability of two types of dental implants, with truncated cone (TC) and cylindrical (CL) geometry, by evaluating their performance by means of pull-out tests. Moreover, several samples were tested by varying surgical preparation method as well as the material where the implant was housed in order to assess whether primary stability could be affected by these factors. A critical load which corresponds to a displacement of 0.2. mm in pull-out test was chosen as indicator of the implant primary stability. CL implants had the advantage of requiring lower torques during the installation phase, and thus, applying less local stresses on the bone. Among the housing preparation methods investigated in the present study, the housings realized by using two mill cutters of different diameters for different depths implied higher primary stability for TC implant.File | Dimensione | Formato | |
---|---|---|---|
Analysis and comparison of clutch techniques of two dental implants.pdf
Accesso chiuso
Descrizione: Articolo principale
Tipologia:
Pdf editoriale (Version of record)
Licenza:
Tutti i diritti riservati
Dimensione
878.82 kB
Formato
Adobe PDF
|
878.82 kB | Adobe PDF | Richiedi una copia |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.