Abstract An increase has been observed not only in the absolute number of CT examinations but also in the length of coverage and number of scanning phases, with the result that exposure to ionising radiation from CT is becoming an increasingly serious problem. The extent of the problem is not entirely known and cannot be adequately addressed without proper knowledge of all the phases that leads to the effective dose calculation. In light of the growing awareness of the issue of ionising radiation dose and the possible risk for the individual and the population, there is a need for radiologists, medical physicists and radiographers to play an active role in dose management. In this review, the authors try to delineate the problem in a consequential and multifaceted way: radiation–patient interaction, possible mechanisms of damage, main CT dose units, risk and its quantification in the population, with the aim of optimising the acquisition dose without diagnostic drawbacks. For an ‘‘up-to-date’’ use of CT, radiologists must know the dose concerns for the single patient and population, and use the CT apparatus with the best dose care; substitute CT with other diagnostic techniques when possible, especially in children; reduce the number/extension of scans and phases, and the dose in single scans and single examinations.

CT exposure in adult and paediatric patients: a review of the mechanisms of damage, relative dose and consequent possible risks / Stefano Colagrande;Daniela Origgi;Giovanna Zatelli;Andrea Giovagnoni;Sergio Salerno. - In: LA RADIOLOGIA MEDICA. - ISSN 0033-8362. - ELETTRONICO. - (2014), pp. 1-8. [10.1007/s11547-014-0393-0]

CT exposure in adult and paediatric patients: a review of the mechanisms of damage, relative dose and consequent possible risks

COLAGRANDE, STEFANO;
2014

Abstract

Abstract An increase has been observed not only in the absolute number of CT examinations but also in the length of coverage and number of scanning phases, with the result that exposure to ionising radiation from CT is becoming an increasingly serious problem. The extent of the problem is not entirely known and cannot be adequately addressed without proper knowledge of all the phases that leads to the effective dose calculation. In light of the growing awareness of the issue of ionising radiation dose and the possible risk for the individual and the population, there is a need for radiologists, medical physicists and radiographers to play an active role in dose management. In this review, the authors try to delineate the problem in a consequential and multifaceted way: radiation–patient interaction, possible mechanisms of damage, main CT dose units, risk and its quantification in the population, with the aim of optimising the acquisition dose without diagnostic drawbacks. For an ‘‘up-to-date’’ use of CT, radiologists must know the dose concerns for the single patient and population, and use the CT apparatus with the best dose care; substitute CT with other diagnostic techniques when possible, especially in children; reduce the number/extension of scans and phases, and the dose in single scans and single examinations.
2014
1
8
Stefano Colagrande;Daniela Origgi;Giovanna Zatelli;Andrea Giovagnoni;Sergio Salerno
File in questo prodotto:
File Dimensione Formato  
Rad Med Protezionistica.pdf

Accesso chiuso

Tipologia: Versione finale referata (Postprint, Accepted manuscript)
Licenza: Open Access
Dimensione 336.2 kB
Formato Adobe PDF
336.2 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/850820
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 29
  • ???jsp.display-item.citation.isi??? 29
social impact