A new accelerator experiment to study very forward particle emission in the LHC collider, LHCf, is presented. Because a collision of 7 TeV protons corresponds to 10(17) eV in the laboratory system, our experiment can give a firm base for simulating air showers generated from ultra high energy cosmic rays. This is indispensable information for the ongoing large experiments like TA, Auger and EUSO for the near future. The LHCf detector is composed of three tower electromagnetic calorimeters and scintillating fibers (SciFi) to measure core position of the shower. To avoid multi particle hits, each tower has a small cross section (2cm x 2cm, 3cm x 3cm and 4cmx4cm). We have confirmed that we can measure shower energy with < 5% resolution even using such small calorimeters. A project overview and the results of a beam test carried out in August 2004 at CERN SPS are presented.

LHCf : A new experiment to study very forward particle emission at LHC / Sako, T.; Muraki, Y.; Itow, Y.; Masuda, K.; Matsubara, Y.; Menjo, H.; Obata, Y.; Tanaka, K.; Matsumoto, H.; Kasahara, K.; Torii, S.; Tamura, T.; Yoshida, K.; Haguenauer, M.; Turner, W.C.; Adriani, O.; Bonechi, L.; Bongi, M.; Velasco, J.; Faus, A.. - STAMPA. - (2005), pp. 189-192. (Intervento presentato al convegno 29th International Cosmic Ray Conference).

LHCf : A new experiment to study very forward particle emission at LHC

ADRIANI, OSCAR;BONECHI, LORENZO;BONGI, MASSIMO;
2005

Abstract

A new accelerator experiment to study very forward particle emission in the LHC collider, LHCf, is presented. Because a collision of 7 TeV protons corresponds to 10(17) eV in the laboratory system, our experiment can give a firm base for simulating air showers generated from ultra high energy cosmic rays. This is indispensable information for the ongoing large experiments like TA, Auger and EUSO for the near future. The LHCf detector is composed of three tower electromagnetic calorimeters and scintillating fibers (SciFi) to measure core position of the shower. To avoid multi particle hits, each tower has a small cross section (2cm x 2cm, 3cm x 3cm and 4cmx4cm). We have confirmed that we can measure shower energy with < 5% resolution even using such small calorimeters. A project overview and the results of a beam test carried out in August 2004 at CERN SPS are presented.
2005
Proceedings of the 29th International Cosmic Ray Conference Vol 8: HE 1.5
29th International Cosmic Ray Conference
Sako, T.; Muraki, Y.; Itow, Y.; Masuda, K.; Matsubara, Y.; Menjo, H.; Obata, Y.; Tanaka, K.; Matsumoto, H.; Kasahara, K.; Torii, S.; Tamura, T.; Yoshi...espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/866185
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact