evolved from 2D arrays to 3D arrays. The aim of this work is to compare 2D and 3D diode arrays for pretreatment verification of step&shoot IMRT plans to determine if the acceptance criteria used for the evaluation of the agreement between dose distributions measured with 2D diode matrixes and calculated by TPS are also valid for 3D diode arrays.

Pretreatment dosimetric verification of IMRT plans with 3D diode matrices: preliminary study for the establishment of new tolerance levels / M. Casati; C. Arilli; M.Bucciolini; A. Compagnucci; L.Marrazzo; S.Pallotta; C.Talamonti; E.Vanzi. - ELETTRONICO. - (2013), pp. 40-40. (Intervento presentato al convegno 8° ongresso Nazionale AIFM tenutosi a Torino nel 2013).

Pretreatment dosimetric verification of IMRT plans with 3D diode matrices: preliminary study for the establishment of new tolerance levels .

BUCCIOLINI, MARTA;MARRAZZO, LIVIA;PALLOTTA, STEFANIA;TALAMONTI, CINZIA;VANZI, ELEONORA
2013

Abstract

evolved from 2D arrays to 3D arrays. The aim of this work is to compare 2D and 3D diode arrays for pretreatment verification of step&shoot IMRT plans to determine if the acceptance criteria used for the evaluation of the agreement between dose distributions measured with 2D diode matrixes and calculated by TPS are also valid for 3D diode arrays.
2013
8° Congreso Nazonale AIFM
8° ongresso Nazionale AIFM
Torino
M. Casati; C. Arilli; M.Bucciolini; A. Compagnucci; L.Marrazzo; S.Pallotta; C.Talamonti; E.Vanzi
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/879138
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact