Background: The aim of this in vitro study was the evaluation of the mechanical properties the screws for rapid maxillary expansion (RME).Methods: Three commercially available screws for RME were tested: Leone A2620; Dentaurum Hyrax; Forestadent Palatal Split Screw. All expansion screws were 10 mm in size. For the evaluation of mechanical properties, the screws for RME were adjusted using the same maxillary dental model. An Instron 3365 testing machine with a load cell of 5 kN recorded the forces released by the screws at different amounts of activation (1, 5, 10, 15 and 20 quarters of a turn). Each type of screw was tested 10 times. Comparisons between the forces released by the different types of screws at different amounts of activation were carried out by means of analysis of Kruskal-Wallis test with post-hoc test di Tukey (P < 0.05).Results: The results of this study showed that all 3 expansion devices were able to develop forces that could produce a separation of the palatine processes. The Hyrax and A2620 expanders developed force values over 20 kg and the Palatal Split screws about 16 kg. Both the A2620 and Hyrax expanders showed significantly greater amounts of forces at all the different amounts of activations with respect to the Palatal Split screw.

Evaluation of mechanical properties of three different screws for rapid maxillary expansion / Matteo Camporesi; Lorenzo Franchi; Tiziana Doldo; Efisio Defraia. - In: BIOMEDICAL ENGINEERING ONLINE. - ISSN 1475-925X. - ELETTRONICO. - 12:(2013), pp. 0-0. [10.1186/1475-925X-12-128]

Evaluation of mechanical properties of three different screws for rapid maxillary expansion

CAMPORESI, MATTEO;FRANCHI, LORENZO;DEFRAIA, EFISIO
2013

Abstract

Background: The aim of this in vitro study was the evaluation of the mechanical properties the screws for rapid maxillary expansion (RME).Methods: Three commercially available screws for RME were tested: Leone A2620; Dentaurum Hyrax; Forestadent Palatal Split Screw. All expansion screws were 10 mm in size. For the evaluation of mechanical properties, the screws for RME were adjusted using the same maxillary dental model. An Instron 3365 testing machine with a load cell of 5 kN recorded the forces released by the screws at different amounts of activation (1, 5, 10, 15 and 20 quarters of a turn). Each type of screw was tested 10 times. Comparisons between the forces released by the different types of screws at different amounts of activation were carried out by means of analysis of Kruskal-Wallis test with post-hoc test di Tukey (P < 0.05).Results: The results of this study showed that all 3 expansion devices were able to develop forces that could produce a separation of the palatine processes. The Hyrax and A2620 expanders developed force values over 20 kg and the Palatal Split screws about 16 kg. Both the A2620 and Hyrax expanders showed significantly greater amounts of forces at all the different amounts of activations with respect to the Palatal Split screw.
2013
12
0
0
Matteo Camporesi; Lorenzo Franchi; Tiziana Doldo; Efisio Defraia
File in questo prodotto:
File Dimensione Formato  
1475-925X-12-128.pdf

accesso aperto

Tipologia: Versione finale referata (Postprint, Accepted manuscript)
Licenza: Open Access
Dimensione 2.53 MB
Formato Adobe PDF
2.53 MB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/890925
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 16
social impact