A proficiency test through interlaboratory comparison of radiated emission measurements was carried out in the period of time comprised between May 2012 and May 2013. Nineteen test houses took part in the exercise providing 91 measurement results in total. Measurements were performed in anechoic chambers and in the frequency range comprised between 200 and 3000 MHz. A traveling sample circulated among the laboratories, generating a reference electromagnetic field whose amplitude was a priori known (with uncertainty) but not revealed to the participants until the end of the comparison. Measurement results were provided by the participants in terms of best estimate and uncertainty. The aggregate measurement result is here compared with the a priori known value and its uncertainty. The performance of the laboratories, quantified in terms of two performance statistics selected from ISO 13528, is analyzed and discussed. The measurement uncertainty declared by the laboratories is compared with the dispersion of the measurement results. Aspects concerning the design and conduct of the comparison are also presented and discussed.

Design, Preparation, Conduct, and Result of a Proficiency Test of Radiated Emission Measurements / Carlo F. M. Carobbi; Alessio Bonci; Marco Cati; Carlo Panconi; Michele Borsero; Giuseppe Vizio. - In: IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY. - ISSN 0018-9375. - STAMPA. - 56:(2014), pp. 1251-1261. [10.1109/TEMC.2014.2326732]

Design, Preparation, Conduct, and Result of a Proficiency Test of Radiated Emission Measurements

CAROBBI, CARLO;BONCI, ALESSIO;
2014

Abstract

A proficiency test through interlaboratory comparison of radiated emission measurements was carried out in the period of time comprised between May 2012 and May 2013. Nineteen test houses took part in the exercise providing 91 measurement results in total. Measurements were performed in anechoic chambers and in the frequency range comprised between 200 and 3000 MHz. A traveling sample circulated among the laboratories, generating a reference electromagnetic field whose amplitude was a priori known (with uncertainty) but not revealed to the participants until the end of the comparison. Measurement results were provided by the participants in terms of best estimate and uncertainty. The aggregate measurement result is here compared with the a priori known value and its uncertainty. The performance of the laboratories, quantified in terms of two performance statistics selected from ISO 13528, is analyzed and discussed. The measurement uncertainty declared by the laboratories is compared with the dispersion of the measurement results. Aspects concerning the design and conduct of the comparison are also presented and discussed.
2014
56
1251
1261
Carlo F. M. Carobbi; Alessio Bonci; Marco Cati; Carlo Panconi; Michele Borsero; Giuseppe Vizio
File in questo prodotto:
File Dimensione Formato  
IEEE Trans EMC Dec 2014 - Proficiency test.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 529.16 kB
Formato Adobe PDF
529.16 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/892719
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 38
  • ???jsp.display-item.citation.isi??? 30
social impact