The analysis and design of a multiple residential building, seismically protected by a base isolation system incorporating double friction pendulum sliders as protective devices, are presented in the paper. The building, situated in the suburban area of Florence, is composed of four independent reinforced concrete framed structures, mutually separated by three thermal expansion joints. The plan is L-shaped, with dimensions of about 75 m in the longitudinal direction and about 30 m along the longest side of the transversal direction. These characteristics identify the structure as the largest example of a base-isolated “artificial ground” ever built in Italy. The base isolation solution guarantees lower costs, a much greater performance and a finer architectural look, as compared to a conventional fixed-base anti-seismic design. The characteristics of the building and the isolators, the mechanical properties and the experimental characterization campaign and preliminary sizing carried out on the latter, and the non-linear time-history design and performance assessment analyses developed on the base isolated building are reported in this paper, along with details about the installation of the isolators and the plants, and highlights of the construction works.

Analysis, design, and construction of a base-isolated multiple building structure / Sorace, S; Terenzi, G. - In: ADVANCES IN CIVIL ENGINEERING. - ISSN 1687-8094. - ELETTRONICO. - 2014, Article number 585429:(2014), pp. 1-13. [10.1155/2014/585429]

Analysis, design, and construction of a base-isolated multiple building structure

TERENZI, GLORIA
2014

Abstract

The analysis and design of a multiple residential building, seismically protected by a base isolation system incorporating double friction pendulum sliders as protective devices, are presented in the paper. The building, situated in the suburban area of Florence, is composed of four independent reinforced concrete framed structures, mutually separated by three thermal expansion joints. The plan is L-shaped, with dimensions of about 75 m in the longitudinal direction and about 30 m along the longest side of the transversal direction. These characteristics identify the structure as the largest example of a base-isolated “artificial ground” ever built in Italy. The base isolation solution guarantees lower costs, a much greater performance and a finer architectural look, as compared to a conventional fixed-base anti-seismic design. The characteristics of the building and the isolators, the mechanical properties and the experimental characterization campaign and preliminary sizing carried out on the latter, and the non-linear time-history design and performance assessment analyses developed on the base isolated building are reported in this paper, along with details about the installation of the isolators and the plants, and highlights of the construction works.
2014
2014, Article number 585429
1
13
Sorace, S; Terenzi, G
File in questo prodotto:
File Dimensione Formato  
Sorace-Terenzi_ACE-2014.pdf

accesso aperto

Tipologia: Pdf editoriale (Version of record)
Licenza: Open Access
Dimensione 3.79 MB
Formato Adobe PDF
3.79 MB Adobe PDF