In this work, an electrochemical DNA aptasensor for acetamiprid is presented. The aptasensor is based on a dual signal amplified strategy by employing a gold-polyaniline modified screen-printed electrode as sensor platform and an enzyme-linked label for sensitive detection. The polyaniline-gold nanocomposite modified electrodes were firstly modified with a mixed monolayer of a thiol-tethered DNA aptamer and 6-mercapto-1-hexanol. The acetamiprid solution was then incubated with the aptasensor. An enzyme - Amplified detection scheme, based on the coupling of a streptavidin - Alkaline phosphatase conjugate and secondary biotinylated aptamer was then applied. The enzyme catalyzed the hydrolysis of the electroinactive 1-naphthyl-phosphate to 1-naphthol. This electroactive product was detected by means of differential pulse voltammetry. A calibration curve between 0-200 nM acetamiprid concentration range was obtained.

DNA technology for small molecules sensing: A new approach for Acetamiprid detection / Rapini, Riccardo.; Marrazza, Giovanna. - ELETTRONICO. - (2015), pp. 1-4. [10.1109/AISEM.2015.7066768]

DNA technology for small molecules sensing: A new approach for Acetamiprid detection

RAPINI, RICCARDO;MARRAZZA, GIOVANNA
2015

Abstract

In this work, an electrochemical DNA aptasensor for acetamiprid is presented. The aptasensor is based on a dual signal amplified strategy by employing a gold-polyaniline modified screen-printed electrode as sensor platform and an enzyme-linked label for sensitive detection. The polyaniline-gold nanocomposite modified electrodes were firstly modified with a mixed monolayer of a thiol-tethered DNA aptamer and 6-mercapto-1-hexanol. The acetamiprid solution was then incubated with the aptasensor. An enzyme - Amplified detection scheme, based on the coupling of a streptavidin - Alkaline phosphatase conjugate and secondary biotinylated aptamer was then applied. The enzyme catalyzed the hydrolysis of the electroinactive 1-naphthyl-phosphate to 1-naphthol. This electroactive product was detected by means of differential pulse voltammetry. A calibration curve between 0-200 nM acetamiprid concentration range was obtained.
2015
978-147998591-3
1
4
Rapini, Riccardo.; Marrazza, Giovanna
File in questo prodotto:
File Dimensione Formato  
2015_XVIII AISEM_Rapini.pdf

Accesso chiuso

Tipologia: Versione finale referata (Postprint, Accepted manuscript)
Licenza: Tutti i diritti riservati
Dimensione 282.95 kB
Formato Adobe PDF
282.95 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1008029
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 0
social impact