Wall Shear Stress (WSS), i.e. the tangential force that blood applies to the inner layer of the vessel wall, is associated with arterial remodeling and important cardiovascular diseases like the formation of atherosclerotic plaques. In simple, uniaxial flows, WSS can be derived as the blood viscosity multiplied by the Wall Shear Rate (WSR), i.e. the velocity gradient evaluated in the radial direction. The WSR is typically estimated by measuring the velocity of the blood in the vessel center and by assuming a parabolic velocity profile (Poiseuille model). Unfortunately, this model produces inaccurate results since it does not account for the complex flow configuration present in the vessel. In a different approach, the actual flow profile is measured instantaneously through a multigate technique, but the clutter corrupts the profile in proximity to the wall, i.e. where the WSR should be evaluated, so that the profile should be reconstructed. In this work, realistic multi-physics simulations of a patient-specific carotid bifurcation are used to assess the accuracy of a 2-step method for profile reconstruction and WSR measurement. The estimated WSR matches the model ground-truth with an accuracy of about 10%.

Wall Shear Rate Method Validation through Multi-physics Simulations / Ricci, S.; Swillens, A.; Ramalli, A.; Segers, P.; Tortoli, P.. - ELETTRONICO. - (2015), pp. 1-4. (Intervento presentato al convegno 2015 IEEE International Ultrasonics Symposium (IUS) tenutosi a Taipei, Taiwan nel Ottobre 2015) [10.1109/ULTSYM.2015.0331].

Wall Shear Rate Method Validation through Multi-physics Simulations

RICCI, STEFANO;RAMALLI, ALESSANDRO;TORTOLI, PIERO
2015

Abstract

Wall Shear Stress (WSS), i.e. the tangential force that blood applies to the inner layer of the vessel wall, is associated with arterial remodeling and important cardiovascular diseases like the formation of atherosclerotic plaques. In simple, uniaxial flows, WSS can be derived as the blood viscosity multiplied by the Wall Shear Rate (WSR), i.e. the velocity gradient evaluated in the radial direction. The WSR is typically estimated by measuring the velocity of the blood in the vessel center and by assuming a parabolic velocity profile (Poiseuille model). Unfortunately, this model produces inaccurate results since it does not account for the complex flow configuration present in the vessel. In a different approach, the actual flow profile is measured instantaneously through a multigate technique, but the clutter corrupts the profile in proximity to the wall, i.e. where the WSR should be evaluated, so that the profile should be reconstructed. In this work, realistic multi-physics simulations of a patient-specific carotid bifurcation are used to assess the accuracy of a 2-step method for profile reconstruction and WSR measurement. The estimated WSR matches the model ground-truth with an accuracy of about 10%.
2015
Proceeding of 2015 IEEE Ultrasonics Symposium
2015 IEEE International Ultrasonics Symposium (IUS)
Taipei, Taiwan
Ottobre 2015
Ricci, S.; Swillens, A.; Ramalli, A.; Segers, P.; Tortoli, P.
File in questo prodotto:
File Dimensione Formato  
07329105.pdf

Accesso chiuso

Descrizione: Versione finale
Tipologia: Versione finale referata (Postprint, Accepted manuscript)
Licenza: Tutti i diritti riservati
Dimensione 816.4 kB
Formato Adobe PDF
816.4 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1009153
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact