The quality of Doppler ultrasound blood flow investigations is often affected by a low signal-to-noise ratio due to the weak energy backscattered by erythrocytes flowing in deep vessels. Transmission of coded pulses and matched receive filtering improve the penetration depth while preserving the axial resolution. However, the involved additional computational load has probably so far discouraged the massive implementation of pulse compression methods in real-time Doppler imaging systems. In this paper, we report on the performance obtained by the pulse compression technique applied to (multigate) spectral Doppler imaging. A real-time algorithm was implemented on the ULA-OP research scanner. The results of phantom experiments show that up to 13dB signal-to-noise ratio gain can be obtained when a 5 μs-long linear chirp is transmitted. Furthermore, invivo tests demonstrate that pulse compression is an effective means to increase the penetration depth, by up to 2 cm, in spectral Doppler applications.

Real-Time Pulse Compression in Multigate Spectral Doppler Imaging / Ramalli, A.; Dallai, A.; Boni, E.; Guidi, F.; Ricci, S.; Tortoli, P.. - ELETTRONICO. - (2015), pp. 1-4. (Intervento presentato al convegno 2015 IEEE International Ultrasonics Symposium (IUS) tenutosi a Taipei, Taiwan nel Ottobre 2015) [10.1109/ULTSYM.2015.0418].

Real-Time Pulse Compression in Multigate Spectral Doppler Imaging

RAMALLI, ALESSANDRO;DALLAI, ALESSANDRO;BONI, ENRICO;GUIDI, FRANCESCO;RICCI, STEFANO;TORTOLI, PIERO
2015

Abstract

The quality of Doppler ultrasound blood flow investigations is often affected by a low signal-to-noise ratio due to the weak energy backscattered by erythrocytes flowing in deep vessels. Transmission of coded pulses and matched receive filtering improve the penetration depth while preserving the axial resolution. However, the involved additional computational load has probably so far discouraged the massive implementation of pulse compression methods in real-time Doppler imaging systems. In this paper, we report on the performance obtained by the pulse compression technique applied to (multigate) spectral Doppler imaging. A real-time algorithm was implemented on the ULA-OP research scanner. The results of phantom experiments show that up to 13dB signal-to-noise ratio gain can be obtained when a 5 μs-long linear chirp is transmitted. Furthermore, invivo tests demonstrate that pulse compression is an effective means to increase the penetration depth, by up to 2 cm, in spectral Doppler applications.
2015
Proceeding of 2015 IEEE Ultrasonics Symposium
2015 IEEE International Ultrasonics Symposium (IUS)
Taipei, Taiwan
Ottobre 2015
Ramalli, A.; Dallai, A.; Boni, E.; Guidi, F.; Ricci, S.; Tortoli, P.
File in questo prodotto:
File Dimensione Formato  
07329393.pdf

Accesso chiuso

Descrizione: Versione finale
Tipologia: Versione finale referata (Postprint, Accepted manuscript)
Licenza: Tutti i diritti riservati
Dimensione 3.11 MB
Formato Adobe PDF
3.11 MB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1009155
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0