Parallel beamforming in transmit (PBT) by means of orthogonal frequency division multiplexing (OFDM) was recently applied to increase the frame rate of ultrasound tissue harmonic imaging. OFDM-PBT improves the data acquisition rate by generating, for each transmission event, multiple beams that are allocated to a specific portion of the available transducer bandwidth. Improving the frame rate is however not the only possible application of an increased data acquisition rate. In this paper, OFDM-PBT is exploited to perform multi-focus tissue harmonic imaging for improving the penetration depth and signal to noise ratio (SNR) without affecting the frame rate. Tissue harmonic images of a tissue mimicking phantom were obtained with OFDM-PBT and standard B-mode imaging. Results present improved penetration depth and SNR for OFDM-PBT as compared to standard B-mode. We estimated an improvement of 6 dB of the average SNR, at the expenses of a reduction of the axial resolution (0.7 vs 1.1 mm).

Multi-Focus Tissue Harmonic Images Obtained with Parallel Transmit Beamforming by means of Orthogonal Frequency Division Multiplexing / Demi, Libertario; Giannini, Gabriele; Ramalli, Alessandro; Tortoli, Piero; Mischi, Massimo. - ELETTRONICO. - (2015), pp. 1-4. (Intervento presentato al convegno 2015 IEEE International Ultrasonics Symposium (IUS) tenutosi a Taipei - Taiwan nel October 2015) [10.1109/ULTSYM.2015.0501].

Multi-Focus Tissue Harmonic Images Obtained with Parallel Transmit Beamforming by means of Orthogonal Frequency Division Multiplexing

GIANNINI, GABRIELE;RAMALLI, ALESSANDRO;TORTOLI, PIERO;
2015

Abstract

Parallel beamforming in transmit (PBT) by means of orthogonal frequency division multiplexing (OFDM) was recently applied to increase the frame rate of ultrasound tissue harmonic imaging. OFDM-PBT improves the data acquisition rate by generating, for each transmission event, multiple beams that are allocated to a specific portion of the available transducer bandwidth. Improving the frame rate is however not the only possible application of an increased data acquisition rate. In this paper, OFDM-PBT is exploited to perform multi-focus tissue harmonic imaging for improving the penetration depth and signal to noise ratio (SNR) without affecting the frame rate. Tissue harmonic images of a tissue mimicking phantom were obtained with OFDM-PBT and standard B-mode imaging. Results present improved penetration depth and SNR for OFDM-PBT as compared to standard B-mode. We estimated an improvement of 6 dB of the average SNR, at the expenses of a reduction of the axial resolution (0.7 vs 1.1 mm).
2015
Proceedings of 2015 IEEE Ultrasonics Symposium
2015 IEEE International Ultrasonics Symposium (IUS)
Taipei - Taiwan
October 2015
Demi, Libertario; Giannini, Gabriele; Ramalli, Alessandro; Tortoli, Piero; Mischi, Massimo
File in questo prodotto:
File Dimensione Formato  
Multi-focus tissue harmonic images obtained with parallel transmit beamforming by means of orthogonal frequency division.pdf

Accesso chiuso

Descrizione: Articolo pubblicato
Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 391.08 kB
Formato Adobe PDF
391.08 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1009467
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact