We performed a comprehensive structure validation of both automated and manually generated structures of the 10 targets of the CASD-NMR-2013 effort. We established that automated structure determination protocols are capable of reliably producing structures of comparable accuracy and quality to those generated by a skilled researcher, at least for small, single domain proteins such as the ten targets tested. The most robust results appear to be obtained when NOESY peak lists are used either as the primary input data or to augment chemical shift data without the need to manually filter such lists. A detailed analysis of the long-range NOE restraints generated by the different programs from the same data showed a surprisingly low degree of overlap. Additionally, we found that there was no significant correlation between the extent of the NOE restraint overlap and the accuracy of the structure. This result was surprising given the importance of NOE data in producing good quality structures. We suggest that this could be explained by the information redundancy present in NOEs between atoms contained within a fixed covalent network.

Analysis of the structural quality of the CASD-NMR 2013 entries / Ragan, Timothy J; Fogh, Rasmus H.; Tejero, Roberto; Vranken, Wim; Montelione, Gaetano T.; Rosato, Antonio; Vuister, Geerten W.. - In: JOURNAL OF BIOMOLECULAR NMR. - ISSN 0925-2738. - STAMPA. - 62:(2015), pp. 527-540. [10.1007/s10858-015-9949-0]

Analysis of the structural quality of the CASD-NMR 2013 entries

ROSATO, ANTONIO;
2015

Abstract

We performed a comprehensive structure validation of both automated and manually generated structures of the 10 targets of the CASD-NMR-2013 effort. We established that automated structure determination protocols are capable of reliably producing structures of comparable accuracy and quality to those generated by a skilled researcher, at least for small, single domain proteins such as the ten targets tested. The most robust results appear to be obtained when NOESY peak lists are used either as the primary input data or to augment chemical shift data without the need to manually filter such lists. A detailed analysis of the long-range NOE restraints generated by the different programs from the same data showed a surprisingly low degree of overlap. Additionally, we found that there was no significant correlation between the extent of the NOE restraint overlap and the accuracy of the structure. This result was surprising given the importance of NOE data in producing good quality structures. We suggest that this could be explained by the information redundancy present in NOEs between atoms contained within a fixed covalent network.
2015
62
527
540
Ragan, Timothy J; Fogh, Rasmus H.; Tejero, Roberto; Vranken, Wim; Montelione, Gaetano T.; Rosato, Antonio; Vuister, Geerten W.
File in questo prodotto:
File Dimensione Formato  
Ragan et al CASD-NMR validation paper rev1.pdf

accesso aperto

Descrizione: Main article with supplementary material
Tipologia: Versione finale referata (Postprint, Accepted manuscript)
Licenza: Open Access
Dimensione 7.78 MB
Formato Adobe PDF
7.78 MB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1012443
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact