A methodology for the seismic vulnerability reduction of old masonry towers with external prestressing is presented. It is applied at the Colonial bell-towers of the Cathedral of Colima, Mexico, characterized for being a high seismic area (M>7.5). The 3D FE models are calibrated with experimental data and assessed through nonlinear static approaches including the seismic demand and an accurate validated masonry model. Based on an extensive parametric study on different configurations of old masonry towers, it is selected an optimal prestressing force and device. The Colonial towers are retrofitted with four prestressing devices of FRPs to convert them into a high energy-dissipative reinforced masonry. The external vertical prestressing is included at key points identified in the seismic vulnerability assessment. This technique is in compliance with the demand for architectural conservation and may be located without drilling and unbounded in order to be fully removable. The seismic performance is enhanced by increasing force, displacement, and internal confinement. It is observed an upgrading of 35% and 20% of displacement capacity. With these results it is corroborated that external vertical prestressing allows a substantial increment of ductility for seismic energy dissipation purposes.

Earthquake protection of colonial bell towers in colima, mexico with externally prestressed frps / Preciado, Adolfo; Budelmann, Harald; Bartoli, Gianni. - In: INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE. - ISSN 1558-3058. - ELETTRONICO. - 10:(2016), pp. 499-515. [10.1080/15583058.2014.1003624]

Earthquake protection of colonial bell towers in colima, mexico with externally prestressed frps

BARTOLI, GIANNI
2016

Abstract

A methodology for the seismic vulnerability reduction of old masonry towers with external prestressing is presented. It is applied at the Colonial bell-towers of the Cathedral of Colima, Mexico, characterized for being a high seismic area (M>7.5). The 3D FE models are calibrated with experimental data and assessed through nonlinear static approaches including the seismic demand and an accurate validated masonry model. Based on an extensive parametric study on different configurations of old masonry towers, it is selected an optimal prestressing force and device. The Colonial towers are retrofitted with four prestressing devices of FRPs to convert them into a high energy-dissipative reinforced masonry. The external vertical prestressing is included at key points identified in the seismic vulnerability assessment. This technique is in compliance with the demand for architectural conservation and may be located without drilling and unbounded in order to be fully removable. The seismic performance is enhanced by increasing force, displacement, and internal confinement. It is observed an upgrading of 35% and 20% of displacement capacity. With these results it is corroborated that external vertical prestressing allows a substantial increment of ductility for seismic energy dissipation purposes.
2016
10
499
515
Preciado, Adolfo; Budelmann, Harald; Bartoli, Gianni
File in questo prodotto:
File Dimensione Formato  
2016_Preciado_et_al_Earthquake-protection-of-colonial-bell-towers-in-colima,-mexico-with-externally-prestressed-frps_2016_International-Journal-of-Architectural-Heritage.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 1.89 MB
Formato Adobe PDF
1.89 MB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1065913
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 13
social impact