The frame rate of ultrasound images can be increased by simultaneously transmitting several focused beams along different directions, according to the method called Multi-Line Transmission (MLT). Unfortunately, the interference among beams may generate crosstalk artifacts that can be partially prevented, at the expense of lateral resolution, by applying Tukey apodization on transmission and reception. In this paper we propose to improve the receive crosstalk rejection and the lateral resolution in MLT images by means of the non-linear Filtered Delay Multiply And Sum (F-DMAS) beamformer, which was proved to lower the beam side lobes and to narrow the main lobe. The performance of F-DMAS in MLT is tested and compared to that of standard Delay and Sum (DAS) beamforming with Tukey apodization, both in simulation and experimental phantom image acquisitions. Results show significant improvements in terms of resolution and contrast with a 4-times higher frame rate.

Improved resolution and crosstalk rejection in Multi-Line Transmit ultrasound imaging using Delay Multiply and Sum beamforming / Matrone, Giulia; Ramalli, Alessandro; Savoia, Alessandro Stuart; Tortoli, Piero; Magenes, Giovanni. - ELETTRONICO. - 2016-:(2016), pp. 1-4. (Intervento presentato al convegno 2016 IEEE International Ultrasonics Symposium, IUS 2016 tenutosi a fra nel 2016) [10.1109/ULTSYM.2016.7728480].

Improved resolution and crosstalk rejection in Multi-Line Transmit ultrasound imaging using Delay Multiply and Sum beamforming

RAMALLI, ALESSANDRO;TORTOLI, PIERO;
2016

Abstract

The frame rate of ultrasound images can be increased by simultaneously transmitting several focused beams along different directions, according to the method called Multi-Line Transmission (MLT). Unfortunately, the interference among beams may generate crosstalk artifacts that can be partially prevented, at the expense of lateral resolution, by applying Tukey apodization on transmission and reception. In this paper we propose to improve the receive crosstalk rejection and the lateral resolution in MLT images by means of the non-linear Filtered Delay Multiply And Sum (F-DMAS) beamformer, which was proved to lower the beam side lobes and to narrow the main lobe. The performance of F-DMAS in MLT is tested and compared to that of standard Delay and Sum (DAS) beamforming with Tukey apodization, both in simulation and experimental phantom image acquisitions. Results show significant improvements in terms of resolution and contrast with a 4-times higher frame rate.
2016
IEEE International Ultrasonics Symposium, IUS
2016 IEEE International Ultrasonics Symposium, IUS 2016
fra
2016
Matrone, Giulia; Ramalli, Alessandro; Savoia, Alessandro Stuart; Tortoli, Piero; Magenes, Giovanni
File in questo prodotto:
File Dimensione Formato  
2016 Matrone - IUS - Improved resolution and crosstalk rejection in MLT US imaging using DMAS beamforming.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 243.2 kB
Formato Adobe PDF
243.2 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1079111
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 0
social impact