The applicability of a direct injection UHPLC-MS/MS method for the analysis of several perfluoroalkyl acids (PFAAs) in a wide range of water matrices was investigated. The method is based on the direct injection of 100 µL of centrifuged water sample, without any other sample treatment. Very good method detection limits (0.014–0.44 ng L−1) and excellent intra and inter-day precision (RSD% values in the range 1.8–4.4% and 2.7–5.7%, respectively) were achieved, with a total analysis time of 20 min per sample. A high number of samples – i.e. 8 drinking waters (DW), 12 ground waters (GW), 13 surface waters (SW), 8 influents and 11 effluents of wastewater treatment plants (WWTPIN and WWTPOUT) were processed and the extent of matrix effect (ME) was calculated, highlighting the strong prevalence of |ME| < 20%. The occurrence of |ME| > 50% was occasionally observed only for perfluorooctanesulphonic and perfluorodecanoic acids. Linear discriminant analysis highlighted the great contribution of the sample origin (i.e. DW, GW, SW, WWTPIN and WWTPOUT) to the ME. Partial least square regression (PLS) and leave-one-out cross-validation were performed in order to interpret and predict the signal suppression or enhancement phenomena as a function of physicochemical parameters of water samples (i.e. conductivity, hardness and chemical oxygen demand) and background chromatographic area. The PLS approach resulted only in an approximate screening, due to the low prediction power of the PLS models. However, for most analytes in most samples, the fitted and cross-validated values were such as to correctly distinguish between | ME | higher than 20% or below this limit. PFAAs in the aforementioned water samples were quantified by means of the standard addition method, highlighting their occurrence mainly in WWTP influents and effluents, at concentrations as high as one hundred of µg L−1.

Applicability of the direct injection liquid chromatographic tandem mass spectrometric analytical approach to the sub-ng L-1 determination of perfluoro-alkyl acids in waste, surface, ground and drinking water samples / Ciofi, L.; Renai, L.; Rossini, D.; Ancillotti, C.; Falai, A.; Fibbi, D.; Bruzzoniti, M.C.; Santana-Rodriguez, J.J.; Orlandini, S.; Del Bubba, M.. - In: TALANTA. - ISSN 0039-9140. - STAMPA. - 176:(2018), pp. 412-421. [10.1016/j.talanta.2017.08.052]

Applicability of the direct injection liquid chromatographic tandem mass spectrometric analytical approach to the sub-ng L-1 determination of perfluoro-alkyl acids in waste, surface, ground and drinking water samples

CIOFI, LORENZO;RENAI, LAPO;ROSSINI, DANIELE;ANCILLOTTI, CLAUDIA;ORLANDINI, SERENA;DEL BUBBA, MASSIMO
2018

Abstract

The applicability of a direct injection UHPLC-MS/MS method for the analysis of several perfluoroalkyl acids (PFAAs) in a wide range of water matrices was investigated. The method is based on the direct injection of 100 µL of centrifuged water sample, without any other sample treatment. Very good method detection limits (0.014–0.44 ng L−1) and excellent intra and inter-day precision (RSD% values in the range 1.8–4.4% and 2.7–5.7%, respectively) were achieved, with a total analysis time of 20 min per sample. A high number of samples – i.e. 8 drinking waters (DW), 12 ground waters (GW), 13 surface waters (SW), 8 influents and 11 effluents of wastewater treatment plants (WWTPIN and WWTPOUT) were processed and the extent of matrix effect (ME) was calculated, highlighting the strong prevalence of |ME| < 20%. The occurrence of |ME| > 50% was occasionally observed only for perfluorooctanesulphonic and perfluorodecanoic acids. Linear discriminant analysis highlighted the great contribution of the sample origin (i.e. DW, GW, SW, WWTPIN and WWTPOUT) to the ME. Partial least square regression (PLS) and leave-one-out cross-validation were performed in order to interpret and predict the signal suppression or enhancement phenomena as a function of physicochemical parameters of water samples (i.e. conductivity, hardness and chemical oxygen demand) and background chromatographic area. The PLS approach resulted only in an approximate screening, due to the low prediction power of the PLS models. However, for most analytes in most samples, the fitted and cross-validated values were such as to correctly distinguish between | ME | higher than 20% or below this limit. PFAAs in the aforementioned water samples were quantified by means of the standard addition method, highlighting their occurrence mainly in WWTP influents and effluents, at concentrations as high as one hundred of µg L−1.
2018
176
412
421
Ciofi, L.; Renai, L.; Rossini, D.; Ancillotti, C.; Falai, A.; Fibbi, D.; Bruzzoniti, M.C.; Santana-Rodriguez, J.J.; Orlandini, S.; Del Bubba, M.
File in questo prodotto:
File Dimensione Formato  
2018_Ciofi-L._Talanta.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 737 kB
Formato Adobe PDF
737 kB Adobe PDF   Richiedi una copia
Preprint_Del Bubba.pdf

accesso aperto

Descrizione: Preprint dell'autore
Tipologia: Altro
Licenza: Creative commons
Dimensione 1.25 MB
Formato Adobe PDF
1.25 MB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1093710
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 37
  • ???jsp.display-item.citation.isi??? 31
social impact