Tissue Harmonic Imaging (THI) mode is currently one of the preferred choices by the clinicians for its ability to provide enhanced ultrasound images, thanks to the use of the second harmonic component of backscattered echoes. This paper aims at investigating whether the combination of THI with Filtered-Delay Multiply And Sum (F-DMAS) beamforming can provide further improvements in image quality. F-DMAS is a new non-linear beamformer, which, similarly to THI, is based on the use of the second harmonics of beamformed signals and is known to increase image contrast resolution and noise rejection. Thus, we have first compared the images obtained by using F-DMAS and the standard Delay And Sum (DAS) beamformers when only the second harmonics of the received signal was selected. Moreover, possible improvements brought about by other harmonic components generated by the combined use of the fundamental plus second harmonics and F-DMAS beamforming have been explored. Experimental results demonstrate that, as compared to standard harmonic imaging with DAS, THI and F-DMAS can be joined to improve the -20 dB lateral resolution up to 1 mm, the contrast ratio up to 12 dB on a cyst-phantom and up to 9 dB on in vivo images.

Experimental Evaluation of Ultrasound Higher-Order Harmonic Imaging with Filtered-Delay Multiply And Sum (F-DMAS) Non-Linear Beamforming / Matrone, Giulia; Ramalli, Alessandro; Tortoli, Piero; Magenes, Giovanni. - In: ULTRASONICS. - ISSN 0041-624X. - ELETTRONICO. - 86:(2018), pp. 59-68. [10.1016/j.ultras.2018.01.002]

Experimental Evaluation of Ultrasound Higher-Order Harmonic Imaging with Filtered-Delay Multiply And Sum (F-DMAS) Non-Linear Beamforming

Ramalli, Alessandro
Membro del Collaboration Group
;
Tortoli, Piero
Membro del Collaboration Group
;
2018

Abstract

Tissue Harmonic Imaging (THI) mode is currently one of the preferred choices by the clinicians for its ability to provide enhanced ultrasound images, thanks to the use of the second harmonic component of backscattered echoes. This paper aims at investigating whether the combination of THI with Filtered-Delay Multiply And Sum (F-DMAS) beamforming can provide further improvements in image quality. F-DMAS is a new non-linear beamformer, which, similarly to THI, is based on the use of the second harmonics of beamformed signals and is known to increase image contrast resolution and noise rejection. Thus, we have first compared the images obtained by using F-DMAS and the standard Delay And Sum (DAS) beamformers when only the second harmonics of the received signal was selected. Moreover, possible improvements brought about by other harmonic components generated by the combined use of the fundamental plus second harmonics and F-DMAS beamforming have been explored. Experimental results demonstrate that, as compared to standard harmonic imaging with DAS, THI and F-DMAS can be joined to improve the -20 dB lateral resolution up to 1 mm, the contrast ratio up to 12 dB on a cyst-phantom and up to 9 dB on in vivo images.
2018
86
59
68
Matrone, Giulia; Ramalli, Alessandro; Tortoli, Piero; Magenes, Giovanni
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1107960
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 30
  • ???jsp.display-item.citation.isi??? 29
social impact