In a group of septic patients, we assess the short-term prognostic value of LV systolic performance, evaluated through conventional left ventricular ejection fraction (LVEF) and left ventricular global longitudinal strain (LV GLS). One hundred forty-seven patients with sepsis were recruited; LVEF by planimetry and peak GLS by 2D speckle tracking could be assessed within 24 h. The study population was stratified according to SOFA tertiles assessed at the time of the echocardiogram (G1: SOFA score <5; G2: SOFA score 5-7; G3: SOFA score >7). Day-7 follow-up data were used as reference. Patients in G2 and G3 show a significant hemodynamic derangement, paralleling the more pronounced organ damage by definition; nevertheless, LVEF and GLS are comparable among the three groups (both p > 0.1). All-cause mortality at day-7 follow-up is slightly lower in G1 (9%) versus G2 and G3 (14 and 26%, respectively, p = NS). Analyses through ROC curves focusing on day-7 mortality show that the SOFA score fairly correlates with events (AUC 0.635, p = 0.037), while low LVEF (AUC 0.35, p = 0.022) and less negative GLS (AUC 0.73, p = 0.001) do so. In multivariate analyses, mortality by day-7 follow-up is more likely per higher GLS (i.e., indicative of worst systolic dysfunction, HR 1.22/%, p = 0.005) and per increasing SOFA score (HR 1.22/unit, p = 0.010), whereas LVEF, adjusted for age and SOFA score, does not enter the prognostic model. In the very short term in patients with severe sepsis, LV systolic function assessment by means of GLS predicts the short-term prognosis, independent of SOFA
SOFA score and left ventricular systolic function as predictors of short-term outcome in patients with sepsis / Innocenti,F.; Palmieri,V.; Guzzo,A.; Stefanone,V.T.; Donnini,C.; Pini,R.. - In: INTERNAL AND EMERGENCY MEDICINE. - ISSN 1828-0447. - STAMPA. - 13:(2018), pp. 51-58. [10.1007/s11739-016-1579-3]
SOFA score and left ventricular systolic function as predictors of short-term outcome in patients with sepsis
Innocenti,F.
;GUZZO, AURELIA MARIA TERESA;Stefanone,V. T.;Donnini,C.;Pini,R.
2018
Abstract
In a group of septic patients, we assess the short-term prognostic value of LV systolic performance, evaluated through conventional left ventricular ejection fraction (LVEF) and left ventricular global longitudinal strain (LV GLS). One hundred forty-seven patients with sepsis were recruited; LVEF by planimetry and peak GLS by 2D speckle tracking could be assessed within 24 h. The study population was stratified according to SOFA tertiles assessed at the time of the echocardiogram (G1: SOFA score <5; G2: SOFA score 5-7; G3: SOFA score >7). Day-7 follow-up data were used as reference. Patients in G2 and G3 show a significant hemodynamic derangement, paralleling the more pronounced organ damage by definition; nevertheless, LVEF and GLS are comparable among the three groups (both p > 0.1). All-cause mortality at day-7 follow-up is slightly lower in G1 (9%) versus G2 and G3 (14 and 26%, respectively, p = NS). Analyses through ROC curves focusing on day-7 mortality show that the SOFA score fairly correlates with events (AUC 0.635, p = 0.037), while low LVEF (AUC 0.35, p = 0.022) and less negative GLS (AUC 0.73, p = 0.001) do so. In multivariate analyses, mortality by day-7 follow-up is more likely per higher GLS (i.e., indicative of worst systolic dysfunction, HR 1.22/%, p = 0.005) and per increasing SOFA score (HR 1.22/unit, p = 0.010), whereas LVEF, adjusted for age and SOFA score, does not enter the prognostic model. In the very short term in patients with severe sepsis, LV systolic function assessment by means of GLS predicts the short-term prognosis, independent of SOFAFile | Dimensione | Formato | |
---|---|---|---|
SOFA Score And Left Ventricular Systolic function.pdf
Accesso chiuso
Descrizione: Articolo principale
Tipologia:
Pdf editoriale (Version of record)
Licenza:
Tutti i diritti riservati
Dimensione
407.39 kB
Formato
Adobe PDF
|
407.39 kB | Adobe PDF | Richiedi una copia |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.