With the first runs of the LHC in 2010 and luminosity upgrades expected from 2016, ATLAS and CMS are planning to upgrade their innermost tracking layers with the ultimate radiation hard technologies. Chemical Vapour Deposition (CVD) diamond has been used extensively in beam conditions monitors as the innermost detectors in the highest radiation areas of BaBar, Belle, CDF and all LHC experiments. This material is now being considered as a sensor material for the innermost layer(s) of the upgraded trackers. Recently the RD42 collaboration constructed, irradiated and tested polycrystalline and single- crystal CVD diamond sensors to the highest fluences expected at the super-LHC. We present beam test results of chemical vapour deposition diamond up to fluences of 1.8x10 16 24 GeV protons/cm 2 illustrating that both polycrystalline and single-crystal chemical vapour deposition diamonds follow a single damage curve. We report preliminary results on polycrystalline diamond from an alternative manufacturer with promising performance. This material is now being considered as a sensor material for the innermost layer(s) of the upgraded trackers . Recently the RD42 collaboration constructed, irradiated and tested polycrystalline and single - crystal CVD diamond sensors to the hi ghest fluences expected at the super - LHC. We present beam test results of chemical vapour deposition diamond up to fl uences of 1 . 8 x 10 16 24 GeV p rotons/cm 2 illustrating that both polycrystalline and single - crystal chemical vapour deposition diamonds follow a single damage curve. We report preliminary results on polycrystalline diamond from an alternative manufacturer with promising performance .
Diamond Detectors / D.Asner , M.Barbero, V.Bellin i , V Belyaev , J-M.Brom, M.Bruzzi , D.Chren, V.Cindro , G.Claus , M.Cristinziani , S Costa , J.Cumalat , R.D'Alessandro , W.de Boer , D.Dobos , I.Dolenc , W.Dulinski , J.Duris , V.Eremin , R.Eusebi , H.Frais-Kölbl , A.Furgeri , C.Galrsapp , K.K.Gan , M.Goffe , J.Goldstein , A.Golubev , A.Gorišek , E.Grigoriev , R.Hall-Wilton , D.Hits , F. Hügging , H.Kagan , R.Kass , G.Kramberger , S.Kuleshov , S.Kwan , S.Lagomarsino , A.La Rosa , A.Lo Giudice , I.Mandić , C.Manfredotti , C.Manfredotti , A.Martemyanov , M.Mathes , D.Menichelli , M.Mikuž , , M.Mishina , J.Moss , S.Müller , G.Oakham , P.Olivero , G.Parrini , H Pernegger , R.Potenza , K.Randrianarivony , A.Robichaud , S.Roe , S.Schnetzer , T.Schreiner , S.Sciortino , S.Smith , B.Sopko , K.Stenson , R.Stone , C.Sutera , W.Trischuk , J-W.Tsung , C.Tuve , J Velthuis , E.Vittone , S.Wagner , R.Wallny , P.Weilhammer , N.Wermes. - In: POS PROCEEDINGS OF SCIENCE. - ISSN 1824-8039. - ELETTRONICO. - (2011), pp. 0-0. [10.22323/1.113.0024]
Diamond Detectors
M. Bruzzi;R. D'Alessandro;S. Lagomarsino;D. Menichelli;G. Parrini;S. Sciortino;
2011
Abstract
With the first runs of the LHC in 2010 and luminosity upgrades expected from 2016, ATLAS and CMS are planning to upgrade their innermost tracking layers with the ultimate radiation hard technologies. Chemical Vapour Deposition (CVD) diamond has been used extensively in beam conditions monitors as the innermost detectors in the highest radiation areas of BaBar, Belle, CDF and all LHC experiments. This material is now being considered as a sensor material for the innermost layer(s) of the upgraded trackers. Recently the RD42 collaboration constructed, irradiated and tested polycrystalline and single- crystal CVD diamond sensors to the highest fluences expected at the super-LHC. We present beam test results of chemical vapour deposition diamond up to fluences of 1.8x10 16 24 GeV protons/cm 2 illustrating that both polycrystalline and single-crystal chemical vapour deposition diamonds follow a single damage curve. We report preliminary results on polycrystalline diamond from an alternative manufacturer with promising performance. This material is now being considered as a sensor material for the innermost layer(s) of the upgraded trackers . Recently the RD42 collaboration constructed, irradiated and tested polycrystalline and single - crystal CVD diamond sensors to the hi ghest fluences expected at the super - LHC. We present beam test results of chemical vapour deposition diamond up to fl uences of 1 . 8 x 10 16 24 GeV p rotons/cm 2 illustrating that both polycrystalline and single - crystal chemical vapour deposition diamonds follow a single damage curve. We report preliminary results on polycrystalline diamond from an alternative manufacturer with promising performance .File | Dimensione | Formato | |
---|---|---|---|
VERTEX 2010_024.pdf
accesso aperto
Tipologia:
Pdf editoriale (Version of record)
Licenza:
Creative commons
Dimensione
396.13 kB
Formato
Adobe PDF
|
396.13 kB | Adobe PDF |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.