The 2010 Maule Chile earthquake (Mw 8.8) caused extensive structural damage to the built heritage. In particular, the poor seismic performance of a set of unreinforced masonry (URM) churches highlighted the need to implement protective and safety strategies in order to preserve these buildings which exhibit unique constructive and typological features, as a result of a combination of Chilean and European construction cultures.The peculiarity of this heritage and the high seismic hazard of Chilean territory have motivated the present study which aims to apply systematic procedures to assess the seismic vulnerability of these buildings. This article is of archival nature and presents a complete database generated from the geometrical, constructive, and structural characteristics of a representative stock of 106 churches located in central Chile, with the goal of proposing fragility curves to be used in seismic risk assessment. Considering variables related with geometrical, architectonic, and stylistic features, as well as damage levels for the 2010 Maule earthquake, this church sample is classified into three homogenous groups: colonial, neo-classic, and neo-gothic. Moreover, a reliminary qualitative assessment of the seismic capacity of these structures is provided using a survey and analysis of geometric indices for each of the three selected groups.

Preliminary Assessment on Seismic Vulnerability of Masonry Churches in Central Chile / Palazzi N.C.; Rovero L.; De La Llera J.C.; Sandoval C.. - In: INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE. - ISSN 1558-3058. - ELETTRONICO. - 14:(2020), pp. 824-848. [10.1080/15583058.2019.1570388]

Preliminary Assessment on Seismic Vulnerability of Masonry Churches in Central Chile

Palazzi N. C.
;
Rovero L.;
2020

Abstract

The 2010 Maule Chile earthquake (Mw 8.8) caused extensive structural damage to the built heritage. In particular, the poor seismic performance of a set of unreinforced masonry (URM) churches highlighted the need to implement protective and safety strategies in order to preserve these buildings which exhibit unique constructive and typological features, as a result of a combination of Chilean and European construction cultures.The peculiarity of this heritage and the high seismic hazard of Chilean territory have motivated the present study which aims to apply systematic procedures to assess the seismic vulnerability of these buildings. This article is of archival nature and presents a complete database generated from the geometrical, constructive, and structural characteristics of a representative stock of 106 churches located in central Chile, with the goal of proposing fragility curves to be used in seismic risk assessment. Considering variables related with geometrical, architectonic, and stylistic features, as well as damage levels for the 2010 Maule earthquake, this church sample is classified into three homogenous groups: colonial, neo-classic, and neo-gothic. Moreover, a reliminary qualitative assessment of the seismic capacity of these structures is provided using a survey and analysis of geometric indices for each of the three selected groups.
2020
14
824
848
Goal 9: Industry, Innovation, and Infrastructure
Palazzi N.C.; Rovero L.; De La Llera J.C.; Sandoval C.
File in questo prodotto:
File Dimensione Formato  
Preliminary Assessment on Seismic Vulnerability of Masonry Churches in Central Chile.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 4.19 MB
Formato Adobe PDF
4.19 MB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1178398
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 22
social impact