One of the current challenges in ultrasound imaging is achieving higher frame rates, particularly in cardiac applications, where tracking the heart motion and other rapid events can provide potential valuable diagnostic information. The main drawback of ultrasound high frame rate strategies is that usually they partly sacrifice image quality in order to speed-up the acquisition time. In particular, multi-line transmission (MLT), which consists in transmitting multiple ultrasound beams simultaneously in different directions, has been proven able to improve frame rates in echocardiography, unfortunately generating artifacts due to inter-beam crosstalk interferences. This work investigates the possibility to effectively suppress crosstalk artifacts in MLT, while improving image quality by applying beamforming techniques based on backscattered signals spatial coherence. Several coherence-based algorithms (i.e. Short-Lag Filtered Delay Multiply and Sum beamforming, Coherence and Generalized Coherence Factor, Phase and Sign Coherence, non-linear beamforming with p-root compression) are implemented and compared, and their performance trends are evaluated when varying their design parameters. Indeed, experimental results of phantom and in vivo cardiac acquisitions demonstrate that this class of algorithms can provide significant benefits as compared to Delay and Sum, well suppressing artifacts (up to 48.5 dB lower crosstalk) and increasing image resolution (by up to 46.3%) and contrast (by up to 30 dB in terms of contrast ratio, and 12.6% for generalized contrast-to-noise ratio) at the same time.
A Comparison of Coherence-Based Beamforming Techniques in High Frame-Rate Ultrasound Imaging with Multi-Line Transmission / Matrone, Giulia; Ramalli, Alessandro; d'Hooge, Jan; Tortoli, Piero; Magenes, Giovanni. - In: IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL. - ISSN 1525-8955. - ELETTRONICO. - 67:(2020), pp. 329-340. [10.1109/TUFFC.2019.2945365]
A Comparison of Coherence-Based Beamforming Techniques in High Frame-Rate Ultrasound Imaging with Multi-Line Transmission
Ramalli, AlessandroMembro del Collaboration Group
;Tortoli, PieroMembro del Collaboration Group
;
2020
Abstract
One of the current challenges in ultrasound imaging is achieving higher frame rates, particularly in cardiac applications, where tracking the heart motion and other rapid events can provide potential valuable diagnostic information. The main drawback of ultrasound high frame rate strategies is that usually they partly sacrifice image quality in order to speed-up the acquisition time. In particular, multi-line transmission (MLT), which consists in transmitting multiple ultrasound beams simultaneously in different directions, has been proven able to improve frame rates in echocardiography, unfortunately generating artifacts due to inter-beam crosstalk interferences. This work investigates the possibility to effectively suppress crosstalk artifacts in MLT, while improving image quality by applying beamforming techniques based on backscattered signals spatial coherence. Several coherence-based algorithms (i.e. Short-Lag Filtered Delay Multiply and Sum beamforming, Coherence and Generalized Coherence Factor, Phase and Sign Coherence, non-linear beamforming with p-root compression) are implemented and compared, and their performance trends are evaluated when varying their design parameters. Indeed, experimental results of phantom and in vivo cardiac acquisitions demonstrate that this class of algorithms can provide significant benefits as compared to Delay and Sum, well suppressing artifacts (up to 48.5 dB lower crosstalk) and increasing image resolution (by up to 46.3%) and contrast (by up to 30 dB in terms of contrast ratio, and 12.6% for generalized contrast-to-noise ratio) at the same time.File | Dimensione | Formato | |
---|---|---|---|
TUFFC2945365_submittedCopyright2.pdf
Open Access dal 07/04/2020
Tipologia:
Versione finale referata (Postprint, Accepted manuscript)
Licenza:
Tutti i diritti riservati
Dimensione
9.92 MB
Formato
Adobe PDF
|
9.92 MB | Adobe PDF |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.