2-D sparse arrays may push the development of low-cost 3-D systems, not needing to control thousands of elements by expensive application-specific integrated circuits. However, there is still some concern about their suitability in applications, such as Doppler investigation, which inherently involve poor signal-to-noise ratios (SNRs). In this paper, a novel real-time 3-D pulsed-wave Doppler system, based on a 256-element 2-D spiral array, is presented. Coded transmission and matched filtering were implemented to improve the system SNR. Standard sonograms as well as multigate spectral Doppler (MSD) profiles, along lines that can be arbitrarily located in different planes, are presented. The performance of the system was assessed quantitatively on experimental data obtained from a straight tube flow phantom. An SNR increase of 11.4 dB was measured by transmitting linear chirps instead of standard sinusoidal bursts. For a qualitative assessment of the system performance in more realistic conditions, an anthropomorphic phantom of the carotid arteries was used. Finally, real-time B-mode and MSD images were obtained from healthy volunteers.

Real-time 3-D Spectral Doppler Analysis with a Sparse Spiral Array / Ramalli, Alessandro; Boni, Enrico; Giangrossi, Claudio; Mattesini, Paolo; Dallai, Alessandro; Liebgott, Herve; Tortoli, Piero. - In: IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL. - ISSN 0885-3010. - STAMPA. - 68:(2021), pp. 1742-1751. [10.1109/TUFFC.2021.3051628]

Real-time 3-D Spectral Doppler Analysis with a Sparse Spiral Array

Ramalli, Alessandro;Boni, Enrico;Giangrossi, Claudio;Mattesini, Paolo;Dallai, Alessandro;Liebgott, Herve;Tortoli, Piero
2021

Abstract

2-D sparse arrays may push the development of low-cost 3-D systems, not needing to control thousands of elements by expensive application-specific integrated circuits. However, there is still some concern about their suitability in applications, such as Doppler investigation, which inherently involve poor signal-to-noise ratios (SNRs). In this paper, a novel real-time 3-D pulsed-wave Doppler system, based on a 256-element 2-D spiral array, is presented. Coded transmission and matched filtering were implemented to improve the system SNR. Standard sonograms as well as multigate spectral Doppler (MSD) profiles, along lines that can be arbitrarily located in different planes, are presented. The performance of the system was assessed quantitatively on experimental data obtained from a straight tube flow phantom. An SNR increase of 11.4 dB was measured by transmitting linear chirps instead of standard sinusoidal bursts. For a qualitative assessment of the system performance in more realistic conditions, an anthropomorphic phantom of the carotid arteries was used. Finally, real-time B-mode and MSD images were obtained from healthy volunteers.
2021
68
1742
1751
Ramalli, Alessandro; Boni, Enrico; Giangrossi, Claudio; Mattesini, Paolo; Dallai, Alessandro; Liebgott, Herve; Tortoli, Piero
File in questo prodotto:
File Dimensione Formato  
09324811_.pdf

Accesso chiuso

Descrizione: Articolo Principale
Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 6.43 MB
Formato Adobe PDF
6.43 MB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1223298
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 9
social impact