We demonstrate a method of light phase shift measurement using a high-finesse optical ring cavity which exhibits reduced phase noise due to cavity length fluctuations. Two laser beams with a frequency difference of one cavity free spectral range are simultaneously resonant with the cavity, demonstrating noise correlations in the error signals due to the common-mode cavity length fluctuations. The differential error signal shows a 30 dB reduction in cavity noise down to the noise floor in a frequency range up to half the cavity linewidth (~ 30 kHz). Various noise sources are analyzed and their contributions to the noise floor are evaluated. Additionally, we apply this noise-reduced phase shift measurement scheme in a simulated spin-squeezing experiment where we have achieved a factor of 40 improvement in phase sensitivity with a phase resolution of 0.7 mrad, which may remove one important barrier against attaining highly spin-squeezed states. The demonstrated method provides a flexible situation by using an optical ring cavity and two independent beams. This method can find direct application to nondestructive measurements in quantum systems, such as for the generation of spin-squeezed states in atom interferometers and atomic clocks.

Method for the differential measurement of phase shifts induced by atoms in an optical ring cavity / Wang, Enlong; Verma, Gunjan; Tinsley, Jonathan N.; Poli, Nicola; Salvi, Leonardo. - In: PHYSICAL REVIEW A. - ISSN 2469-9926. - ELETTRONICO. - 103:(2021), pp. 022609-022609. [10.1103/PhysRevA.103.022609]

Method for the differential measurement of phase shifts induced by atoms in an optical ring cavity

Wang, Enlong;Tinsley, Jonathan N.;Poli, Nicola;Salvi, Leonardo
2021

Abstract

We demonstrate a method of light phase shift measurement using a high-finesse optical ring cavity which exhibits reduced phase noise due to cavity length fluctuations. Two laser beams with a frequency difference of one cavity free spectral range are simultaneously resonant with the cavity, demonstrating noise correlations in the error signals due to the common-mode cavity length fluctuations. The differential error signal shows a 30 dB reduction in cavity noise down to the noise floor in a frequency range up to half the cavity linewidth (~ 30 kHz). Various noise sources are analyzed and their contributions to the noise floor are evaluated. Additionally, we apply this noise-reduced phase shift measurement scheme in a simulated spin-squeezing experiment where we have achieved a factor of 40 improvement in phase sensitivity with a phase resolution of 0.7 mrad, which may remove one important barrier against attaining highly spin-squeezed states. The demonstrated method provides a flexible situation by using an optical ring cavity and two independent beams. This method can find direct application to nondestructive measurements in quantum systems, such as for the generation of spin-squeezed states in atom interferometers and atomic clocks.
2021
103
022609
022609
Wang, Enlong; Verma, Gunjan; Tinsley, Jonathan N.; Poli, Nicola; Salvi, Leonardo
File in questo prodotto:
File Dimensione Formato  
PhysRevA.103.022609.pdf

accesso aperto

Descrizione: main article
Tipologia: Pdf editoriale (Version of record)
Licenza: Open Access
Dimensione 1.54 MB
Formato Adobe PDF
1.54 MB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1234653
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact