Volumetric ultrasound imaging of blood flow with microbubbles enables more complete visualization of the microvasculature. Sparse arrays are ideal candidates to perform volumetric imaging at reduced manufacturing complexity and cable count. However, due to the small number of transducer elements, sparse arrays often come with high clutter levels, especially when wide beams are transmitted to increase the frame rate. In this study, we demonstrate with a prototype sparse array probe and a diverging wave transmission strategy, that a uniform transmission field can be achieved. With the implementation of a spatial coherence beamformer, background clutter signal can be effectively suppressed, leading to a signal to background ratio improvement of 25 dB. With this approach, we demonstrate the volumetric visualization of single microbubbles in a tissue-mimicking phantom as well as vasculature mapping in a live chicken embryo chorioallantoic membrane.

High Frame Rate Volumetric Imaging of Microbubbles Using a Sparse Array and Spatial Coherence Beamforming / Wei L.; Wahyulaksana G.; Meijlink B.; Ramalli A.; Noothout E.; Verweij M.; Boni E.; Kooiman K.; Van der Steen A.F.; Tortoli P.; De Jong N.; Vos H.J.. - In: IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL. - ISSN 0885-3010. - ELETTRONICO. - 68:(2021), pp. 3069-3081. [10.1109/TUFFC.2021.3086597]

High Frame Rate Volumetric Imaging of Microbubbles Using a Sparse Array and Spatial Coherence Beamforming

Ramalli A.
Membro del Collaboration Group
;
Boni E.
Membro del Collaboration Group
;
Tortoli P.
Membro del Collaboration Group
;
2021

Abstract

Volumetric ultrasound imaging of blood flow with microbubbles enables more complete visualization of the microvasculature. Sparse arrays are ideal candidates to perform volumetric imaging at reduced manufacturing complexity and cable count. However, due to the small number of transducer elements, sparse arrays often come with high clutter levels, especially when wide beams are transmitted to increase the frame rate. In this study, we demonstrate with a prototype sparse array probe and a diverging wave transmission strategy, that a uniform transmission field can be achieved. With the implementation of a spatial coherence beamformer, background clutter signal can be effectively suppressed, leading to a signal to background ratio improvement of 25 dB. With this approach, we demonstrate the volumetric visualization of single microbubbles in a tissue-mimicking phantom as well as vasculature mapping in a live chicken embryo chorioallantoic membrane.
2021
68
3069
3081
Wei L.; Wahyulaksana G.; Meijlink B.; Ramalli A.; Noothout E.; Verweij M.; Boni E.; Kooiman K.; Van der Steen A.F.; Tortoli P.; De Jong N.; Vos H.J....espandi
File in questo prodotto:
File Dimensione Formato  
09446938.pdf

accesso aperto

Descrizione: Articolo Principale, Preprint
Tipologia: Pdf editoriale (Version of record)
Licenza: Creative commons
Dimensione 2.62 MB
Formato Adobe PDF
2.62 MB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1239066
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 20
social impact