The ELI-NP facility (Extreme Light Infrastructure-Nuclear Physics) will deliver an intense and almost monochromatic gamma beam for frontier research in nuclear physics. Peculiar devices and techniques have been developed to measure and monitor the beam parameters during the commissioning and the operational phase. In this work we will present the Compton Spectrometer, designed to reconstruct the γ beam energy spectrum, by measuring the energy and the position of Compton scattered electrons. The energy and the angle of the scattered electron are measured by a High Purity Germanium detector and a double sided silicon strip detector. The associated photon is detected in coincidence with the electron by barium fluoride (BaF2) crystals for trigger purpose. In this work we report the status of the characterization carried out on the detectors composing the spectrometer.
A compton spectrometer to monitor the ELI-NP gamma beam energy / Borgheresi R.; Adriani O.; Albergo S.; Andreotti M.; Cappello G.; Cardarelli P.; Ciaranfi R.; Consoli E.; Di Domenico G.; Evangelisti F.; Gambaccini M.; Graziani G.; Lenzi M.; Maletta F.; Marziani M.; Passaleva G.; Paterno G.; Serban A.; Squerzanti S.; Starodubstev O.; Tricomi A.; Variola A.; Veltri M.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - ELETTRONICO. - 936:(2019), pp. 107-109. [10.1016/j.nima.2018.09.104]
A compton spectrometer to monitor the ELI-NP gamma beam energy
Borgheresi R.;Adriani O.;Graziani G.;Lenzi M.;Passaleva G.;Tricomi A.;
2019
Abstract
The ELI-NP facility (Extreme Light Infrastructure-Nuclear Physics) will deliver an intense and almost monochromatic gamma beam for frontier research in nuclear physics. Peculiar devices and techniques have been developed to measure and monitor the beam parameters during the commissioning and the operational phase. In this work we will present the Compton Spectrometer, designed to reconstruct the γ beam energy spectrum, by measuring the energy and the position of Compton scattered electrons. The energy and the angle of the scattered electron are measured by a High Purity Germanium detector and a double sided silicon strip detector. The associated photon is detected in coincidence with the electron by barium fluoride (BaF2) crystals for trigger purpose. In this work we report the status of the characterization carried out on the detectors composing the spectrometer.File | Dimensione | Formato | |
---|---|---|---|
1-s2.0-S0168900218312579-main.pdf
Accesso chiuso
Tipologia:
Pdf editoriale (Version of record)
Licenza:
Tutti i diritti riservati
Dimensione
408.98 kB
Formato
Adobe PDF
|
408.98 kB | Adobe PDF | Richiedi una copia |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.