In museums, poor indoor air quality combined with unsuitable thermal and hygrometric conditions can affect the visitors and staff wellbeing as well as cause the deterioration processes of the exhibit objects. In order to assess indoor air quality of the museum, a survey was carried out in some rooms of the Uffizi Gallery of Florence by the researchers of the Laboratory of Environmental Physics of the University of Florence. Indoor temperature, relative humidity, chemical and microbiological pollutants were sampled, and the results analyzed and discussed. To do that a general methodology of investigation and evaluation of the results was defined and applied to several rooms of the Gallery. The presence of critical pollutant concentration was underlined and proper investigations on the HVAC system were scheduled. In this paper the results regarding a representative room are shown and discussed.

Uffizi Gallery monitoring for IAQ assessment / Carletti, Cristina; Cellai, Gianfranco; Piselli, Cristina; Sciurpi, Fabio; Russo, Giuseppe; Schmidt, Eike D.. - In: E3S WEB OF CONFERENCES. - ISSN 2267-1242. - ELETTRONICO. - 343:(2022), pp. 0-0. (Intervento presentato al convegno “HVAC and Health, Comfort, Environment - Equipments and Design for IEQ and Sustainability” tenutosi a Vicenza nel 03-04/09/2021) [10.1051/e3sconf/202234302002].

Uffizi Gallery monitoring for IAQ assessment

Carletti, Cristina;Cellai, Gianfranco;Piselli, Cristina;Sciurpi, Fabio;
2022

Abstract

In museums, poor indoor air quality combined with unsuitable thermal and hygrometric conditions can affect the visitors and staff wellbeing as well as cause the deterioration processes of the exhibit objects. In order to assess indoor air quality of the museum, a survey was carried out in some rooms of the Uffizi Gallery of Florence by the researchers of the Laboratory of Environmental Physics of the University of Florence. Indoor temperature, relative humidity, chemical and microbiological pollutants were sampled, and the results analyzed and discussed. To do that a general methodology of investigation and evaluation of the results was defined and applied to several rooms of the Gallery. The presence of critical pollutant concentration was underlined and proper investigations on the HVAC system were scheduled. In this paper the results regarding a representative room are shown and discussed.
2022
52nd AiCARR International Conference “HVAC and Health, Comfort, Environment - Equipments and Design for IEQ and Sustainability”
“HVAC and Health, Comfort, Environment - Equipments and Design for IEQ and Sustainability”
Vicenza
03-04/09/2021
Goal 7: Affordable and clean energy
Goal 13: Climate action
Carletti, Cristina; Cellai, Gianfranco; Piselli, Cristina; Sciurpi, Fabio; Russo, Giuseppe; Schmidt, Eike D.
File in questo prodotto:
File Dimensione Formato  
e3sconf_52ndaicarr2022_02002.pdf

accesso aperto

Tipologia: Versione finale referata (Postprint, Accepted manuscript)
Licenza: Open Access
Dimensione 2.38 MB
Formato Adobe PDF
2.38 MB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1260409
Citazioni
  • ???jsp.display-item.citation.pmc??? ND