The aim of this paper was to analyze, using computational fluid dynamics (CFD), a heating system in a commercial broiler house. Data were collected in a broiler house located in the western mesoregion of Minas Gerais, Brazil. The data were collected at 10 a.m. on the seventh day of chicks’ life in 16 points inside the house. A tetrahedral mesh was adopted for the simulation, and testing of the mesh yielded a geometry of 485,691 nodes. The proposed model was developed in a permanent state condition to simulate the temperature air inside the broiler house, and all other input variables were considered constant. The applied CFD technique resulted in satisfactory fitting of the air temperature variable along the broiler facility as a function of the input data. The results indicated that the model predicted the environmental conditions inside the broiler house very accurately. The mean error of the CFD model was 1.49%, indicating that the model is effective and therefore that it can be used in other applications. The results showed that the heating system provided favorable thermoneutral conditions for chicks in the biggest part of the broiler house. However, there were some areas with air temperature above and below the thermoneutral zone.

Three-Dimensional Simulation of the Temperature Distribution in a Commercial Broiler House / Ferraz, Patrícia Ferreira Ponciano; Andrade, Ednilton Tavares de; Vilas Boas, Regina Batista; Rezende, Renan Pereira; Yanagi Junior, Tadayuki; Barbari, Matteo. - In: ANIMALS. - ISSN 2076-2615. - ELETTRONICO. - 12:(2022), pp. 1-10. [10.3390/ani12101278]

Three-Dimensional Simulation of the Temperature Distribution in a Commercial Broiler House

Barbari, Matteo
2022

Abstract

The aim of this paper was to analyze, using computational fluid dynamics (CFD), a heating system in a commercial broiler house. Data were collected in a broiler house located in the western mesoregion of Minas Gerais, Brazil. The data were collected at 10 a.m. on the seventh day of chicks’ life in 16 points inside the house. A tetrahedral mesh was adopted for the simulation, and testing of the mesh yielded a geometry of 485,691 nodes. The proposed model was developed in a permanent state condition to simulate the temperature air inside the broiler house, and all other input variables were considered constant. The applied CFD technique resulted in satisfactory fitting of the air temperature variable along the broiler facility as a function of the input data. The results indicated that the model predicted the environmental conditions inside the broiler house very accurately. The mean error of the CFD model was 1.49%, indicating that the model is effective and therefore that it can be used in other applications. The results showed that the heating system provided favorable thermoneutral conditions for chicks in the biggest part of the broiler house. However, there were some areas with air temperature above and below the thermoneutral zone.
2022
12
1
10
Goal 12: Responsible consumption and production
Ferraz, Patrícia Ferreira Ponciano; Andrade, Ednilton Tavares de; Vilas Boas, Regina Batista; Rezende, Renan Pereira; Yanagi Junior, Tadayuki; Barbari...espandi
File in questo prodotto:
File Dimensione Formato  
animals-12-01278.pdf

accesso aperto

Descrizione: Pubblicazione finale
Tipologia: Pdf editoriale (Version of record)
Licenza: Open Access
Dimensione 1.97 MB
Formato Adobe PDF
1.97 MB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1269235
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact