Coherent multi-transducer ultrasound (CoMTUS) imaging enables the use of multiple arrays as one large effective aperture. This yields images with enlarged field-of-view, improved resolution, and higher SNR. However, creating a large but discontinuous effective aperture increases the grating and side lobe levels and generates cross-talk artifacts from the direct transmissions between arrays. These additional challenges can degrade the contrast of the images obtained through the classic Delay and Sum (DAS) beamforming algorithm. This study investigates the use of an alternative nonlinear beamforming algorithm, the Delay Multiply and Sum (DMAS), to improve contrast and reduce cross-talk artifacts in CoMTUS. We adapted the original DMAS beamforming algorithm to the specific effective aperture of CoMTUS and tested its performance in a coherent dual-array system for both 2-D and 3-D imaging. The comparison between images obtained through CoMTUS DMAS and DAS was investigated by both 2-D and 3-D simulations and experiments. DMAS was shown effective to lower the side lobes and the noise floor, thus improving the detectability of cystic lesions.

Specific Delay Multiply and Sum Beamforming for 2-D and 3-D Coherent Multi-Transducer Ultrasound imaging / Peralta, Laura; Mazierli, Daniele; Hajnal, Joseph V; Tortoli, Piero; Ramalli, Alessandro. - ELETTRONICO. - (2022), pp. 1-3. (Intervento presentato al convegno 2022 IEEE International Ultrasonics Symposium (IUS) tenutosi a Venezia) [10.1109/IUS54386.2022.9957263].

Specific Delay Multiply and Sum Beamforming for 2-D and 3-D Coherent Multi-Transducer Ultrasound imaging

Mazierli, Daniele;Tortoli, Piero;Ramalli, Alessandro
2022

Abstract

Coherent multi-transducer ultrasound (CoMTUS) imaging enables the use of multiple arrays as one large effective aperture. This yields images with enlarged field-of-view, improved resolution, and higher SNR. However, creating a large but discontinuous effective aperture increases the grating and side lobe levels and generates cross-talk artifacts from the direct transmissions between arrays. These additional challenges can degrade the contrast of the images obtained through the classic Delay and Sum (DAS) beamforming algorithm. This study investigates the use of an alternative nonlinear beamforming algorithm, the Delay Multiply and Sum (DMAS), to improve contrast and reduce cross-talk artifacts in CoMTUS. We adapted the original DMAS beamforming algorithm to the specific effective aperture of CoMTUS and tested its performance in a coherent dual-array system for both 2-D and 3-D imaging. The comparison between images obtained through CoMTUS DMAS and DAS was investigated by both 2-D and 3-D simulations and experiments. DMAS was shown effective to lower the side lobes and the noise floor, thus improving the detectability of cystic lesions.
2022
2022 IEEE International Ultrasonics Symposium (IUS)
2022 IEEE International Ultrasonics Symposium (IUS)
Venezia
Peralta, Laura; Mazierli, Daniele; Hajnal, Joseph V; Tortoli, Piero; Ramalli, Alessandro
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1294640
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact