Introduction: The aim of the work is to analyze stress distribution on 3D Finite Element (FE) models at bone, implant, and framework level of different designs for fixed implant-supported prostheses in completely edentulous patients, comparing results on whole and partially resected mandibles. Materials and methods: 3D anisotropic FE models of a whole and of a partially resected mandible were created using a TC scan of a cadaver's totally edentulous mandible. Two types of totally implant-supported rehabilitation were simulated, with four implants: parallel fixtures on whole mandible and on resected mandible, All-on-four-configured fixtures on whole mandible and on partially resected mandible. A superstructure comprising only metal components of a prosthetic framework were added, while stress distribution and its maximum values were analyzed at bone, implant, and superstructure level. Results: The results highlight that: 1) implant stresses are greater on the whole mandible than on the resected one; 2) framework and cancellous-bone stresses are comparable in all cases; 3) on the resected mandible, maximum stress levels at the cortical-bone/implant interface are higher than in whole-mandible rehabilitation. The opposite applies for maximum stresses on external cortical bone, measured radially with respect to the implant from the point of maximum stress at the interface. Discussion: On the resected mandible, All-on-four configuration proved biomechanically superior to parallel implants considering radial stresses on implants and cortical bone. Still, maximum stresses increase at the bone/implant interface. A design with four parallel implants minimizes the stress on a resected mandible while, on the whole mandible, the All-on-four rehabilitation proves superior at all levels (bone, implant, and framework).
Is All-on-four effective in case of partial mandibular resection? A 3D finite element study / Dario, Vangi; Michelangelo-Santo, Gulino; Roberto, Branchi; Fabio, Ferretti. - In: JOURNAL OF STOMATOLOGY, ORAL AND MAXILLOFACIAL SURGERY. - ISSN 2468-7855. - ELETTRONICO. - (2023), pp. 101463-101472. [10.1016/j.jormas.2023.101463]
Is All-on-four effective in case of partial mandibular resection? A 3D finite element study
Dario, Vangi;Michelangelo-Santo, Gulino
;Roberto, Branchi;Fabio, Ferretti
2023
Abstract
Introduction: The aim of the work is to analyze stress distribution on 3D Finite Element (FE) models at bone, implant, and framework level of different designs for fixed implant-supported prostheses in completely edentulous patients, comparing results on whole and partially resected mandibles. Materials and methods: 3D anisotropic FE models of a whole and of a partially resected mandible were created using a TC scan of a cadaver's totally edentulous mandible. Two types of totally implant-supported rehabilitation were simulated, with four implants: parallel fixtures on whole mandible and on resected mandible, All-on-four-configured fixtures on whole mandible and on partially resected mandible. A superstructure comprising only metal components of a prosthetic framework were added, while stress distribution and its maximum values were analyzed at bone, implant, and superstructure level. Results: The results highlight that: 1) implant stresses are greater on the whole mandible than on the resected one; 2) framework and cancellous-bone stresses are comparable in all cases; 3) on the resected mandible, maximum stress levels at the cortical-bone/implant interface are higher than in whole-mandible rehabilitation. The opposite applies for maximum stresses on external cortical bone, measured radially with respect to the implant from the point of maximum stress at the interface. Discussion: On the resected mandible, All-on-four configuration proved biomechanically superior to parallel implants considering radial stresses on implants and cortical bone. Still, maximum stresses increase at the bone/implant interface. A design with four parallel implants minimizes the stress on a resected mandible while, on the whole mandible, the All-on-four rehabilitation proves superior at all levels (bone, implant, and framework).File | Dimensione | Formato | |
---|---|---|---|
1-s2.0-S246878552300085X-main.pdf
accesso aperto
Tipologia:
Pdf editoriale (Version of record)
Licenza:
Open Access
Dimensione
4.3 MB
Formato
Adobe PDF
|
4.3 MB | Adobe PDF |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.