Introduction: Aim of the study was to evaluate perioperative, postoperative and mid-term functional outcomes of Florence intracorporeal neobladder (FloRIN) configuration technique performed with stentless procedure.Materials and methods: This single institution randomized 1:1 prospective series included consecutive patients treated with Robot-Assisted Radical Cystectomy (RARC) and FloRIN reconfiguration from January 2021 to February 2022. Postoperative complications were graded according to Clavien Dindo classification and divided in early (<30 days from discharge) and delayed (>30 days).Results: Overall, 63 patients were included in the analysis. Among these 32 (50.8 %) were treated with RARC + stentless FloRIN while 31 (49.2 %) underwent stent placement procedure. No differences were found in terms of baseline characteristics between the two groups. Stentless procedure was associated with significant shorter console time 328 vs 374 min (p = 0.04) and lower estimated blood loss (EBL) 330 vs 350 ml (p = 0.04) comparing to stent group. As regards perioperative features, no significant differences were recorded in terms of canalization (p = 0.58) and time to drainage removal (p = 0.11) while a shorter length of hospital stay was found in case of stentless procedure (p = 0.04). Early postoperative complications Clavien >= 3a occurred in 9.3 % and 12.9 % of patients while delayed major complications were recorded in the 3.1 % and 9.6 % of patients treated with stentless and stent FloRIN, respectively (p = 0.09). As regards the mid-term functional outcomes, no differences were found in terms of kidney function loss in both 3rd and 6th month assessment (p = 0.13 and p = 0.14, respectively).Conclusions: In conclusion, Stentless FloRIN is a feasible and safe IntraCorporeal Neobladder technique, as confirmed by the worthy functional and perioperative outcomes achieved in comparison with the standard FloRIN ureteral management strategy.

Stentless florence robotic intracorporeal neobladder (FloRIN), a feasibility prospective randomized clinical trial / Lambertini, Luca; Di Maida, Fabrizio; Cadenar, Anna; Nardoni, Samuele; Grosso, Antonio Andrea; Valastro, Francesca; Spinelli, Pietro; Fantechi, Riccardo; Tuccio, Agostino; Vittori, Gianni; Mari, Andrea; Masieri, Lorenzo; Minervini, Andrea. - In: EUROPEAN JOURNAL OF SURGICAL ONCOLOGY. - ISSN 0748-7983. - ELETTRONICO. - 50:(2024), pp. 107259.0-107259.0. [10.1016/j.ejso.2023.107259]

Stentless florence robotic intracorporeal neobladder (FloRIN), a feasibility prospective randomized clinical trial

Lambertini, Luca;Di Maida, Fabrizio;Cadenar, Anna;Nardoni, Samuele;Grosso, Antonio Andrea;Valastro, Francesca;Spinelli, Pietro;Fantechi, Riccardo;Tuccio, Agostino;Vittori, Gianni;Mari, Andrea;Masieri, Lorenzo;Minervini, Andrea
2024

Abstract

Introduction: Aim of the study was to evaluate perioperative, postoperative and mid-term functional outcomes of Florence intracorporeal neobladder (FloRIN) configuration technique performed with stentless procedure.Materials and methods: This single institution randomized 1:1 prospective series included consecutive patients treated with Robot-Assisted Radical Cystectomy (RARC) and FloRIN reconfiguration from January 2021 to February 2022. Postoperative complications were graded according to Clavien Dindo classification and divided in early (<30 days from discharge) and delayed (>30 days).Results: Overall, 63 patients were included in the analysis. Among these 32 (50.8 %) were treated with RARC + stentless FloRIN while 31 (49.2 %) underwent stent placement procedure. No differences were found in terms of baseline characteristics between the two groups. Stentless procedure was associated with significant shorter console time 328 vs 374 min (p = 0.04) and lower estimated blood loss (EBL) 330 vs 350 ml (p = 0.04) comparing to stent group. As regards perioperative features, no significant differences were recorded in terms of canalization (p = 0.58) and time to drainage removal (p = 0.11) while a shorter length of hospital stay was found in case of stentless procedure (p = 0.04). Early postoperative complications Clavien >= 3a occurred in 9.3 % and 12.9 % of patients while delayed major complications were recorded in the 3.1 % and 9.6 % of patients treated with stentless and stent FloRIN, respectively (p = 0.09). As regards the mid-term functional outcomes, no differences were found in terms of kidney function loss in both 3rd and 6th month assessment (p = 0.13 and p = 0.14, respectively).Conclusions: In conclusion, Stentless FloRIN is a feasible and safe IntraCorporeal Neobladder technique, as confirmed by the worthy functional and perioperative outcomes achieved in comparison with the standard FloRIN ureteral management strategy.
2024
50
0
0
Goal 3: Good health and well-being
Lambertini, Luca; Di Maida, Fabrizio; Cadenar, Anna; Nardoni, Samuele; Grosso, Antonio Andrea; Valastro, Francesca; Spinelli, Pietro; Fantechi, Riccar...espandi
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0748798323008971-main.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Solo lettura
Dimensione 410.58 kB
Formato Adobe PDF
410.58 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1357916
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact