An innovative SPME head space GC–MS method, in cooling mode, using a fully automated routine, was developed to detect 2-phenyl-2-propanol, a representative urinary metabolite of cumene. Following an acid hydrolysis and derivatization step with lowered quantities of reagents, acetic anhydride and pyridine, a 30 μm polydimethylsiloxane SPME fiber was used to sample derivatized 2-phenyl-2-propanol, such as benzenemethanol,α,α-dimethyl-acetate, from the headspace. Performances of the method, optimized through experimental design, provide an LOD of 0.034 mg/L and an LOQ 0.10 mg/L, with a short sampling time necessary per sample. The method, developed on standard solutions, will be applied to both occupationally exposed and non-exposed populations.

Regarding Bioanalysis Lasting a Few Minutes: Automated Cooling-SPME and Fast-GC for Urinary 2-Phenyl-2-Propanol Monitoring / Dugheri S.; Fanfani N.; Cappelli G.; Marigliano A.; Bucaletti E.; Squillaci D.; Rapi I.; Venturini L.; Pizzella G.; Manetta S.; Pavone A.; Secchi M.; Rainaldi I.; Mucci N.. - In: TOXICS. - ISSN 2305-6304. - ELETTRONICO. - 12:(2024), pp. 743.0-743.0. [10.3390/toxics12100743]

Regarding Bioanalysis Lasting a Few Minutes: Automated Cooling-SPME and Fast-GC for Urinary 2-Phenyl-2-Propanol Monitoring

Fanfani N.;Cappelli G.;Marigliano A.;Bucaletti E.;Squillaci D.;Rapi I.;Venturini L.;Mucci N.
2024

Abstract

An innovative SPME head space GC–MS method, in cooling mode, using a fully automated routine, was developed to detect 2-phenyl-2-propanol, a representative urinary metabolite of cumene. Following an acid hydrolysis and derivatization step with lowered quantities of reagents, acetic anhydride and pyridine, a 30 μm polydimethylsiloxane SPME fiber was used to sample derivatized 2-phenyl-2-propanol, such as benzenemethanol,α,α-dimethyl-acetate, from the headspace. Performances of the method, optimized through experimental design, provide an LOD of 0.034 mg/L and an LOQ 0.10 mg/L, with a short sampling time necessary per sample. The method, developed on standard solutions, will be applied to both occupationally exposed and non-exposed populations.
2024
12
0
0
Dugheri S.; Fanfani N.; Cappelli G.; Marigliano A.; Bucaletti E.; Squillaci D.; Rapi I.; Venturini L.; Pizzella G.; Manetta S.; Pavone A.; Secchi M.; ...espandi
File in questo prodotto:
File Dimensione Formato  
toxics-12-00743.pdf

accesso aperto

Tipologia: Pdf editoriale (Version of record)
Licenza: Open Access
Dimensione 1.6 MB
Formato Adobe PDF
1.6 MB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1403693
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact