Keratoconus is an ophthalmic disease in which the cornea acquires an abnormal conical shape that prevents the correct focusing on the retina, causing visual impairment. The late diagnosis of keratoconus is among the principal causes of corneal transplantation surgery. In several previous studies, a different organization sutural lamellae was observed in keratoconic corneas compared to healthy corneas. This study is intended to investigate this anomaly by means of Second Harmonic Generation (SHG) microscopy, using an optical scheme relevant for clinical applications. In particular, we propose a method based on 3D correlation of SHG image stacks, able to appreciate statistical differences in the orientation distribution of sutural lamellae between healthy and keratoconic corneas. The proposed method offers the potential for diagnosing keratoconus in an early stage.

Morphological characterizazion of human keratoconic corneas by SHG microscopy / Mercatelli R.; Ratto F.; Rossi F.; Tatini F.; Menabuoni L.; Nicoletti R.; Pini R.; Pavone F.S.; Cicchi R.. - ELETTRONICO. - 2016:(2016), pp. 0-0. ( 18th Italian National Conference on Photonic Technologies, Fotonica 2016 ita 2016).

Morphological characterizazion of human keratoconic corneas by SHG microscopy

Mercatelli R.;Ratto F.;Rossi F.;Tatini F.;Nicoletti R.;Pini R.;Pavone F. S.;Cicchi R.
2016

Abstract

Keratoconus is an ophthalmic disease in which the cornea acquires an abnormal conical shape that prevents the correct focusing on the retina, causing visual impairment. The late diagnosis of keratoconus is among the principal causes of corneal transplantation surgery. In several previous studies, a different organization sutural lamellae was observed in keratoconic corneas compared to healthy corneas. This study is intended to investigate this anomaly by means of Second Harmonic Generation (SHG) microscopy, using an optical scheme relevant for clinical applications. In particular, we propose a method based on 3D correlation of SHG image stacks, able to appreciate statistical differences in the orientation distribution of sutural lamellae between healthy and keratoconic corneas. The proposed method offers the potential for diagnosing keratoconus in an early stage.
2016
IET Conference Publications
18th Italian National Conference on Photonic Technologies, Fotonica 2016
ita
2016
Mercatelli R.; Ratto F.; Rossi F.; Tatini F.; Menabuoni L.; Nicoletti R.; Pini R.; Pavone F.S.; Cicchi R.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1452681
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact