Doppler-based velocity estimation requires accurate knowledge of the beam-to-flow angle. Current threedimensional (3D) methods often rely on computationally demanding algorithms, such as volumetric speckle tracking or cross-correlation, which are difficult to execute in real-time. This paper presents a lightweight and robust procedure for Doppler angle estimation, which extends the two-dimensional method based on Spectral Symmetry Index (SSI) calculation to 3D using a matrix array probe. After vessel localization, a focused (reference) beam is dynamically steered across angle pairs , to sample a pyramidal angular volume. Multigate spectral Doppler (MSD) profiles are calculated for each angle pair, and SSI values are evaluated. A two-step coarse-to-fine scan refines the flow direction identification. Experimental validation was performed using a fully-parallel 1024-channel open ultrasound research platform and a commercial flow phantom scanned across 5 vessel orientations and 3 flow velocities. An angular estimation accuracy better than ± 1% was achieved, demonstrating robust performance.

3D Doppler Angle Estimation Using Spectral Symmetry and Matrix Arrays / Paolo Verdi, A.R.. - ELETTRONICO. - (In corso di stampa), pp. 1-3. (2026 IEEE Ultrasonics Symposium Raleigh (USA) 4-8/10/2026).

3D Doppler Angle Estimation Using Spectral Symmetry and Matrix Arrays

Paolo Verdi
Writing – Original Draft Preparation
;
Alessandro Ramalli
Supervision
;
Enrico Boni
Membro del Collaboration Group
;
Piero Tortoli
Writing – Review & Editing
;
In corso di stampa

Abstract

Doppler-based velocity estimation requires accurate knowledge of the beam-to-flow angle. Current threedimensional (3D) methods often rely on computationally demanding algorithms, such as volumetric speckle tracking or cross-correlation, which are difficult to execute in real-time. This paper presents a lightweight and robust procedure for Doppler angle estimation, which extends the two-dimensional method based on Spectral Symmetry Index (SSI) calculation to 3D using a matrix array probe. After vessel localization, a focused (reference) beam is dynamically steered across angle pairs , to sample a pyramidal angular volume. Multigate spectral Doppler (MSD) profiles are calculated for each angle pair, and SSI values are evaluated. A two-step coarse-to-fine scan refines the flow direction identification. Experimental validation was performed using a fully-parallel 1024-channel open ultrasound research platform and a commercial flow phantom scanned across 5 vessel orientations and 3 flow velocities. An angular estimation accuracy better than ± 1% was achieved, demonstrating robust performance.
In corso di stampa
2026 IEEE Ultrasonics Symposium Proceedings
2026 IEEE Ultrasonics Symposium
Raleigh (USA)
4-8/10/2026
Paolo Verdi, Alessandro Ramalli, Enrico Boni, Piero Tortoli, Barbara Nicolas, Philippe Joos, Hervé Liebgott
File in questo prodotto:
File Dimensione Formato  
2026_IUS_Verdi.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Solo lettura
Dimensione 267.12 kB
Formato Adobe PDF
267.12 kB Adobe PDF   Richiedi una copia all'autore

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1496132
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact