Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
The KM3NeT Collaboration is incrementally building and operating two underwater Cherenkov neutrino telescopes, composed by modular units named DOMs (for Digital Optical Module), each one hosting 31 photomultipliers, and arranged in strings of 18, named DUs (for Detection Unit) anchored to the sea bed and kept in tension by a buoy. One telescope, named ORCA, will consist of a single building block of 115 DUs, whereas the larger one, ARCA, will consist of 2 building blocks for a total of 230 strings, i.e. ~4,000 DOMs and ~130,000 photomultipliers. Efficiently controlling so many objects is challenging, with the inevitable variety of network, hardware and firmware generations that can be expected in a multi-decade project such as KM3NeT. The Control Unit software has the task to maximise the livetime of the detector, automatically handling most common operations as well as several exceptional conditions, in a context where communications are not trivial and the controlled endpoints are instrumented devices floating in the seawater. The Control Unit collects incoming monitoring data from each DOM, including tiltmeter/compass data that help continuously reconstructing the changing shape of the detector in the currents, while at the same time it ensures that all DOMs and photomultipliers swiftly react to operating parameter adjustment requests. The architectural choices are discussed on a quantitative footing showing the increasing challenges of growing, complex machines. The evolution of the Control Unit software is taking place while the telescopes are taking valuable data, providing relevant physics output to the scientific community.
Scaling the Control Unit of KM3NeT to full detector / Bouasla A.B., Attallah R., Adriani O., Albert A., Alhebsi A.R., Alshalloudi S., Alshamsi M., Alves Garre S., Ameli F., Andre M., Aphecetche L., Ardid M., Ardid S., Aublin J., Badaracco F., Bailly-Salins L., Baret B., Bariego-Quintana A., Barnard M., Becherini Y., et al.. - In: POS PROCEEDINGS OF SCIENCE. - ISSN 1824-8039. - ELETTRONICO. - 501:(2025), pp. 0-0. (39th International Cosmic Ray Conference, ICRC 2025 2025) [10.22323/1.501.0993].
Scaling the Control Unit of KM3NeT to full detector
Bouasla A. B.;Attallah R.;Adriani O.;Albert A.;Alhebsi A. R.;Alshalloudi S.;Alshamsi M.;Alves Garre S.;Ameli F.;Andre M.;Aphecetche L.;Ardid M.;Ardid S.;Aublin J.;Badaracco F.;Bailly-Salins L.;Baret B.;Bariego-Quintana A.;Barnard M.;Becherini Y.;Bendahman M.;Benfenati Gualandi F.;Benhassi M.;Benoit D. M.;Benusova Z.;Berbee E.;Berti E.;Bertin V.;Betti P.;Biagi S.;Boettcher M.;Bonanno D.;Bondi M.;Bottai S.;Bouasla A. B.;Boumaaza J.;Bouta M.;Bouwhuis M.;Bozza C.;Bozza R. M.;Branzas H.;Bretaudeau F.;Breuhaus M.;Bruijn R.;Brunner J.;Bruno R.;Buis E.;Buompane R.;Burriel I.;Busto J.;Caiffi B.;Calvo D.;Capone A.;Carenini F.;Carretero V.;Cartraud T.;Castaldi P.;Cecchini V.;Celli S.;Cerisy L.;Chabab M.;Chen A.;Cherubini S.;Chiarusi T.;Chung W.;Circella M.;Clark R.;Cocimano R.;Coelho J. A. B.;Coleiro A.;Condorelli A.;Coniglione R.;Coyle P.;Creusot A.;Cuttone G.;Dallier R.;De Benedittis A.;De Wasseige G.;Decoene V.;Deguire P.;Del Rosso I.;Di Mauro L. S.;Di Palma I.;Diaz A. F.;Diego-Tortosa D.;Distefano C.;Domi A.;Donzaud C.;Dornic D.;Drakopoulou E.;Drouhin D.;Ducoin J. -G.;Duverne P.;Dvornicky R.;Eberl T.;Eckerova E.;Eddymaoui A.;van Eeden T.;Eff M.;van Eijk D.;El Bojaddaini I.;El Hedri S.;El Mentawi S.;Ellajosyula V.;Enzenhofer A.;Farino M.;Ferrara G.;Filipovic M. D.;Filippini F.;Franciotti D.;Fusco L. A.;Gal T.;Garcia Mendez J.;Garcia Soto A.;Gatius Oliver C.;Geisselbrecht N.;Genton E.;Ghaddari H.;Gialanella L.;Gibson B. K.;Giorgio E.;Goos I.;Goswami P.;Gozzini S. R.;Gracia R.;Guillon B.;Haack C.;Hanna C.;van Haren H.;Hazelton E.;Heijboer A.;Hennig L.;Hernandez-Rey J. J.;Idrissi A.;Idrissi Ibnsalih W.;Illuminati G.;Jaimes R.;Janik O.;Joly D.;de Jong M.;de Jong P.;Jung B. J.;Kalaczynski P.;Katz U. F.;Keegans J.;Kikvadze V.;Kistauri G.;Kopper C.;Kouchner A.;Kovalev Y. Y.;Krupa L.;Kueviakoe V.;Kulikovskiy V.;Kvatadze R.;Labalme M.;Lahmann R.;Lamoureux M.;Langella A.;Larosa G.;Lastoria C.;Lazar J.;Lazo A.;Lehaut G.;Lemaitre V.;Leonora E.;Lessing N.;Levi G.;Lindsey Clark M.;Longhitano F.;Madarapu S.;Magnani F.;Malerba L.;Mamedov F.;Manfreda A.;Manousakis A.;Marconi M.;Margiotta A.;Marinelli A.;Markou C.;Martin L.;Mastrodicasa M.;Mastroianni S.;Mauro J.;Mehta K. C. K.;Miele G.;Migliozzi P.;Migneco E.;Mitsou M. L.;Mollo C. M.;Morales-Gallegos L.;Mori N.;Moussa A.;Mozun Mateo I.;Muller R.;Musone M. R.;Musumeci M.;Navas S.;Nayerhoda A.;Nicolau C. A.;Nkosi B.;Fearraigh B. O.;Oliviero V.;Orlando A.;Oukacha E.;Pacini L.;Paesani D.;Palacios Gonzalez J.;Papalashvili G.;Papini P.;Parisi V.;Parmar A.;Pastore C.;Paun A. M.;Pavalas G. E.;Pena Martinez S.;Perrin-Terrin M.;Pestel V.;Petropavlova M.;Piattelli P.;Plavin A.;Poire C.;Popa V.;Pradier T.;Prado J.;Pulvirenti S.;Quiroz-Rangel C. A.;Randazzo N.;Ratnani A.;Razzaque S.;Rea I. C.;Real D.;Riccobene G.;Robinson J.;Romanov A.;Ros E.;Saina A.;Salesa Greus F.;Samtleben D. F. E.;Sanchez Losa A.;Sanfilippo S.;Sanguineti M.;Santonocito D.;Sapienza P.;Scaringella M.;Scarnera M.;Schnabel J.;Schumann J.;Seneca J.;Sevle Myhr P. A.;Sgura I.;Shanidze R.;Shao C.;Sharma A.;Shitov Y.;Simkovic F.;Simonelli A.;Sinopoulou A.;Spisso B.;Spurio M.;Starodubtsev O.;Stavropoulos D.;Stekl I.;Stocco D.;Taiuti M.;Tayalati Y.;Thiersen H.;Tosta e Melo I.;Trocme B.;Tsourapis V.;Tully C.;Tzamariudaki E.;Ukleja A.;Vacheret A.;Valsecchi V.;Van Elewyck V.;Vannoye G.;Vannuccini E.;Vasileiadis G.;Vazquez de Sola F.;Veutro A.;Viola S.;Vivolo D.;van Vliet A.;de Wolf E.;Lhenry-Yvon I.;Zavatarelli S.;Zito D.;Zornoza J. D.;Zuniga J.
2025
Abstract
The KM3NeT Collaboration is incrementally building and operating two underwater Cherenkov neutrino telescopes, composed by modular units named DOMs (for Digital Optical Module), each one hosting 31 photomultipliers, and arranged in strings of 18, named DUs (for Detection Unit) anchored to the sea bed and kept in tension by a buoy. One telescope, named ORCA, will consist of a single building block of 115 DUs, whereas the larger one, ARCA, will consist of 2 building blocks for a total of 230 strings, i.e. ~4,000 DOMs and ~130,000 photomultipliers. Efficiently controlling so many objects is challenging, with the inevitable variety of network, hardware and firmware generations that can be expected in a multi-decade project such as KM3NeT. The Control Unit software has the task to maximise the livetime of the detector, automatically handling most common operations as well as several exceptional conditions, in a context where communications are not trivial and the controlled endpoints are instrumented devices floating in the seawater. The Control Unit collects incoming monitoring data from each DOM, including tiltmeter/compass data that help continuously reconstructing the changing shape of the detector in the currents, while at the same time it ensures that all DOMs and photomultipliers swiftly react to operating parameter adjustment requests. The architectural choices are discussed on a quantitative footing showing the increasing challenges of growing, complex machines. The evolution of the Control Unit software is taking place while the telescopes are taking valuable data, providing relevant physics output to the scientific community.
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1500356
Citazioni
ND
0
ND
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.