Dynamic monitoring and identification are widely used in structural engineering for assessing the seismic behaviour of buildings. These techniques are particularly suitable for monumental masonry buildings, which have remarkable complexity, both in the geometry and material heterogeneity, and cannot be investigated through destructive surveys. However, monitoring data can be influenced by accidental occurrences and atmospheric agents. Because temperature and humidity variations affect the dynamic behaviour of buildings, long-term monitoring is required to achieve a reliable assessment of modal frequencies and consequently mechanical properties. This article presents the results of an extensive two-year dynamic and thermal-hygrometric monitoring campaign carried out on the Arnolfo tower within the Palazzo Vecchio, one of the most significant historical buildings in Florence. This monitoring provided a substantial dataset of the two main modal frequencies of the tower, which was compared to the ambient conditions observed during monitoring. Numerical simulations, carried out considering the experimental frequency variability range, allowed us to evaluate the effect of the frequency variation on the Young’s modulus hypothesised for the building.

Long-term dynamic monitoring of a masonry tower: a case study of Arnolfo Tower within Palazzo Vecchio in Florence, Italy / Tanganelli, M., Azzara, R.M., Trovatelli, F., Viti, S.. - In: BUILT HERITAGE. - ISSN 2662-6802. - STAMPA. - 10:(2026), pp. 1-17. [10.1186/s43238-026-00322-3]

Long-term dynamic monitoring of a masonry tower: a case study of Arnolfo Tower within Palazzo Vecchio in Florence, Italy

Tanganelli, Marco
;
Azzara, Riccardo Mario;Trovatelli, Francesco;Viti, Stefania
2026

Abstract

Dynamic monitoring and identification are widely used in structural engineering for assessing the seismic behaviour of buildings. These techniques are particularly suitable for monumental masonry buildings, which have remarkable complexity, both in the geometry and material heterogeneity, and cannot be investigated through destructive surveys. However, monitoring data can be influenced by accidental occurrences and atmospheric agents. Because temperature and humidity variations affect the dynamic behaviour of buildings, long-term monitoring is required to achieve a reliable assessment of modal frequencies and consequently mechanical properties. This article presents the results of an extensive two-year dynamic and thermal-hygrometric monitoring campaign carried out on the Arnolfo tower within the Palazzo Vecchio, one of the most significant historical buildings in Florence. This monitoring provided a substantial dataset of the two main modal frequencies of the tower, which was compared to the ambient conditions observed during monitoring. Numerical simulations, carried out considering the experimental frequency variability range, allowed us to evaluate the effect of the frequency variation on the Young’s modulus hypothesised for the building.
2026
10
1
17
Tanganelli, Marco; Azzara, Riccardo Mario; Trovatelli, Francesco; Viti, Stefania
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1502065
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact