Gating of single-photon emission computed tomography (SPECT) has significantly improved the reliability and diagnostic accuracy of myocardial perfusion imaging. The functional parameters derived from this technique, mainly left ventricular volumes and ejection fraction, have been demonstrated to be accurate and reproducible. They are able to increase the detection of severe and extensive coronary artery disease and show a significant incremental prognostic power over perfusion abnormalities. Therefore, the importance given to gated SPECT functional data has progressively grown. Discussion: This circumstance has further expanded the indications for myocardial perfusion imaging and strengthened its position among the different imaging modalities. Moreover, several studies show that the evaluation of ventricular function may have a leading part in justifying the execution of perfusion scintigraphy in various clinical conditions. Aim: Aim of this review is to describe this evolution of gated SPECT functional assessment from a supporting rank with respect to perfusion, to a main actor position in the field of cardiac imaging

The expanding role of left ventricular functional assessment using gated myocardial perfusion SPECT: the supporting actor is stealing the scene / R. SCIAGRA'. - In: EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING. - ISSN 1619-7070. - STAMPA. - 34:(2007), pp. 1107-1122. [10.1007/s00259-007-0405-6]

The expanding role of left ventricular functional assessment using gated myocardial perfusion SPECT: the supporting actor is stealing the scene.

SCIAGRA', ROBERTO
2007

Abstract

Gating of single-photon emission computed tomography (SPECT) has significantly improved the reliability and diagnostic accuracy of myocardial perfusion imaging. The functional parameters derived from this technique, mainly left ventricular volumes and ejection fraction, have been demonstrated to be accurate and reproducible. They are able to increase the detection of severe and extensive coronary artery disease and show a significant incremental prognostic power over perfusion abnormalities. Therefore, the importance given to gated SPECT functional data has progressively grown. Discussion: This circumstance has further expanded the indications for myocardial perfusion imaging and strengthened its position among the different imaging modalities. Moreover, several studies show that the evaluation of ventricular function may have a leading part in justifying the execution of perfusion scintigraphy in various clinical conditions. Aim: Aim of this review is to describe this evolution of gated SPECT functional assessment from a supporting rank with respect to perfusion, to a main actor position in the field of cardiac imaging
2007
34
1107
1122
R. SCIAGRA'
File in questo prodotto:
File Dimensione Formato  
Gated_SPECT_rev.pdf

accesso aperto

Tipologia: Versione finale referata (Postprint, Accepted manuscript)
Licenza: Open Access
Dimensione 557.61 kB
Formato Adobe PDF
557.61 kB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/255997
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 26
  • ???jsp.display-item.citation.isi??? 22
social impact