ABSTRACT - Side-branches and curvatures in the arterial tree yield deviations from the axial oriented velocity. Velocity or volume flow estimates based on the assumption that flow is axially oriented are of limited value at these sites. This article evaluates information obtainable by using a multigate Doppler ultrasound (US) instrument used with curved phantoms, which resemble the human coronary arteries. The comparison of experimental velocity data with data provided by an accurate computational fluid dynamics (CFD) method shows differences in the range of 4 to 11% for four curvatures with different radii. Multigate data are also used to estimate the volume flow in the curved segments at different experimental conditions. An error lower than 15% is obtained, to be compared with a 24% error obtained by assuming a parabolic velocity profile. In particular, it is shown that the residual error is not related to the small deviation of the velocity vectors from the axial direction due to the presence of secondary velocity components, which are found to be of magnitude less than 10% with respect to the axial velocity component.
Effect of vessel curvature on Doppler derived velocity profiles and fluid flow / R. Krams, G. Bambi, F. Guidi, F. Helderman, A. Van der Steen, P. Tortoli. - In: ULTRASOUND IN MEDICINE AND BIOLOGY. - ISSN 0301-5629. - STAMPA. - 31:(2005), pp. 663-671. [10.1016/j.ultrasmedbio.2005.01.011]
Effect of vessel curvature on Doppler derived velocity profiles and fluid flow
G. BambiMembro del Collaboration Group
;F. GuidiMembro del Collaboration Group
;P. Tortoli
Supervision
2005
Abstract
ABSTRACT - Side-branches and curvatures in the arterial tree yield deviations from the axial oriented velocity. Velocity or volume flow estimates based on the assumption that flow is axially oriented are of limited value at these sites. This article evaluates information obtainable by using a multigate Doppler ultrasound (US) instrument used with curved phantoms, which resemble the human coronary arteries. The comparison of experimental velocity data with data provided by an accurate computational fluid dynamics (CFD) method shows differences in the range of 4 to 11% for four curvatures with different radii. Multigate data are also used to estimate the volume flow in the curved segments at different experimental conditions. An error lower than 15% is obtained, to be compared with a 24% error obtained by assuming a parabolic velocity profile. In particular, it is shown that the residual error is not related to the small deviation of the velocity vectors from the axial direction due to the presence of secondary velocity components, which are found to be of magnitude less than 10% with respect to the axial velocity component.File | Dimensione | Formato | |
---|---|---|---|
UMB05_Krams.pdf
Accesso chiuso
Tipologia:
Altro
Licenza:
Tutti i diritti riservati
Dimensione
289.22 kB
Formato
Adobe PDF
|
289.22 kB | Adobe PDF | Richiedi una copia |
EFFECT OF VESSEL CURVATURE ON DOPPLER DERIVED VELOCITY_Abs.pdf
Accesso chiuso
Tipologia:
Altro
Licenza:
Tutti i diritti riservati
Dimensione
25.74 kB
Formato
Adobe PDF
|
25.74 kB | Adobe PDF | Richiedi una copia |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.