Recombinant human interleukin-11 (rhIL-11) treatment given to alleviate side effects of cancer therapy is associated with an increased susceptibility to atrial arrhythmias in elderly patients. To elucidate the mechanism underlying this action, we investigated the direct electrophysiologic effect of rhIL-11 on single human atrial myocytes (HuAM) using the patch-clamp technique. Action potentials (AP) at different driving rates were recorded in the perforated-patch configuration, and L-type calcium current (I(Ca,L)), outward potassium currents (I(to) and I(K)), and the hyperpolarization-activated pacemaker current If were measured in the disrupted whole-cell configuration. At therapeutic concentrations (i.e., 10-100 ng/ml), rhIL-11 did not modify AP parameters and cycle-length dependence of AP duration. I(Ca,L) (measured at 0 mV) was 370 +/- 45 pA in control and 379 +/- 48 pA and 368 +/- 42 pA in the presence of 10 and 50 ng/ml rhIL-11, respectively (p = NS). The amplitude and activation of I(to) were not modified by rhIL-11 (i.e., I(to) was at +60 mV: 2.1 +/- 0.2 nA in control vs. 1.9 +/- 0.2 nA and 2.1 +/- 0.2 nA in the presence of 10 and 50 ng/ml rhIL-11, respectively, p = NS). Similarly, late currents measured at the end of the pulse were unchanged in the presence of 10 or 50 ng/ml of rhIL-11. If activation was not modified by rhIL-11: maximal current was 173 +/- 34 pA in control and 159 +/- 35 pA and 117 +/- 14 pA in the presence of 10 and 50 ng/ml of rhIL-11, respectively; midpoint activation was -99 +/- 3 mV in control and -98 +/- 4 mV and -94 +/- 2 mV in the presence of 10 and 50 ng/ml of rhIL-11, respectively (p = NS). Thus, it is unlikely that direct alterations of membrane potential and currents of HuAM caused by rhIL-11 are the basis for the genesis of atrial arrhythmias observed in patients treated with this agent.
Does recombinant human interleukin 11 exert direct electrophysiologic effects on single human atrial myocytes? / L. SARTIANI; P. DE PAOLI; G. LONARDO; R. PINO; A. CONTI; E. CERBAI; A. PELLEG; L. BELARDINELLI; A. MUGELLI.. - In: JOURNAL OF CARDIOVASCULAR PHARMACOLOGY. - ISSN 0160-2446. - STAMPA. - 39:(2002), pp. 425-434. [10.1097/00005344-200203000-00014]
Does recombinant human interleukin 11 exert direct electrophysiologic effects on single human atrial myocytes?
SARTIANI, LAURA;CONTI, ANDREA;CERBAI, ELISABETTA;MUGELLI, ALESSANDRO
2002
Abstract
Recombinant human interleukin-11 (rhIL-11) treatment given to alleviate side effects of cancer therapy is associated with an increased susceptibility to atrial arrhythmias in elderly patients. To elucidate the mechanism underlying this action, we investigated the direct electrophysiologic effect of rhIL-11 on single human atrial myocytes (HuAM) using the patch-clamp technique. Action potentials (AP) at different driving rates were recorded in the perforated-patch configuration, and L-type calcium current (I(Ca,L)), outward potassium currents (I(to) and I(K)), and the hyperpolarization-activated pacemaker current If were measured in the disrupted whole-cell configuration. At therapeutic concentrations (i.e., 10-100 ng/ml), rhIL-11 did not modify AP parameters and cycle-length dependence of AP duration. I(Ca,L) (measured at 0 mV) was 370 +/- 45 pA in control and 379 +/- 48 pA and 368 +/- 42 pA in the presence of 10 and 50 ng/ml rhIL-11, respectively (p = NS). The amplitude and activation of I(to) were not modified by rhIL-11 (i.e., I(to) was at +60 mV: 2.1 +/- 0.2 nA in control vs. 1.9 +/- 0.2 nA and 2.1 +/- 0.2 nA in the presence of 10 and 50 ng/ml rhIL-11, respectively, p = NS). Similarly, late currents measured at the end of the pulse were unchanged in the presence of 10 or 50 ng/ml of rhIL-11. If activation was not modified by rhIL-11: maximal current was 173 +/- 34 pA in control and 159 +/- 35 pA and 117 +/- 14 pA in the presence of 10 and 50 ng/ml of rhIL-11, respectively; midpoint activation was -99 +/- 3 mV in control and -98 +/- 4 mV and -94 +/- 2 mV in the presence of 10 and 50 ng/ml of rhIL-11, respectively (p = NS). Thus, it is unlikely that direct alterations of membrane potential and currents of HuAM caused by rhIL-11 are the basis for the genesis of atrial arrhythmias observed in patients treated with this agent.File | Dimensione | Formato | |
---|---|---|---|
Sartiani_JCardPharm_2002.pdf
Accesso chiuso
Tipologia:
Versione finale referata (Postprint, Accepted manuscript)
Licenza:
Tutti i diritti riservati
Dimensione
823.99 kB
Formato
Adobe PDF
|
823.99 kB | Adobe PDF | Richiedi una copia |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.