Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
Chemical vapor deposition diamond has been discussed extensively as an alternate sensor material for use very close
to the interaction region of the LHC where extreme radiation conditions exist. During the last few years diamond devices have been manufactured and tested with LHC electronics with the goal of creating a detector usable by all LHC experiment. Extensive progress on diamond quality, on the development of diamond trackers and on radiation hardness studies has been made. Transforming the technology to the LHC specific requirements is now underway. In this paper we present the recent progress achieved.
The development of diamond tracking detectors for the LHC / W. Adam, E. Berdermann, P. Bergonzo, W. De Boer, F. Bogani, E. Borchi, A. Brambilla, M. Bruzzi, C. Colledani, J. Conway, P. D'Angelo, W. Dabrowski, P. Delpierre, J. Doroshenko, W. Dulinski, B. Van Eijk, A. Fallou, P. Fischer, F. Fizzotti, C. Furetta, et al.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 514:(2003), pp. 79-86. [:10.1016/j.nima.2003.08.086]
The development of diamond tracking detectors for the LHC
W. Adam;E. Berdermann;P. Bergonzo;W. De Boer;BOGANI, FRANCO;BORCHI, EMILIO;A. Brambilla;BRUZZI, MARA;C. Colledani;J. Conway;P. D'Angelo;W. Dabrowski;P. Delpierre;J. Doroshenko;W. Dulinski;B. Van Eijk;A. Fallou;P. Fischer;F. Fizzotti;C. Furetta;K. K. Gan;N. Ghodbane;E. Grigoriev;G. Hallewell;S. Han;F. Hartjes;J. Hrubec;D. Husson;H. Kagan;J. Kaplon;C. Karl;R. Kass;M. Keil;K. T. Knopfle;T. Koeth;M. Krammer;A. Logiudice;R. Lu;L. Mac Lynne;C. Manfredotti;R. D. Marshall;D. Meier;MENICHELLI, DAVID;S. Meuser;M. Mishina;L. Moroni;J. Noomen;A. Oh;L. Perera;H. Pernegger;M. Pernicka;P. Polesello;R. Potenza;J. L. Riester;S. Roe;A. Rudge;S. Sala;M. Sampietro;S. Schnetzer;SCIORTINO, SILVIO;H. Stelzer;R. Stone;C. Sutera
2003
Abstract
Chemical vapor deposition diamond has been discussed extensively as an alternate sensor material for use very close
to the interaction region of the LHC where extreme radiation conditions exist. During the last few years diamond devices have been manufactured and tested with LHC electronics with the goal of creating a detector usable by all LHC experiment. Extensive progress on diamond quality, on the development of diamond trackers and on radiation hardness studies has been made. Transforming the technology to the LHC specific requirements is now underway. In this paper we present the recent progress achieved.
W. Adam; E. Berdermann; P. Bergonzo; W. De Boer; F. Bogani; E. Borchi; A. Brambilla; M. Bruzzi; C. Colledani; J. Conway; P. D'Angelo; W. Dabrowski; P....espandi
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/347398
Citazioni
ND
ND
ND
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.