Volumetric blood flow measurements require the assessment of both the velocity distribution and the cross-sectional area of the vessel. Unfortunately several difficulties hamper such a measurement in standard approaches. A new dual beam method has been recently introduced in which the Doppler spectral symmetry is exploited to finely orientating the first beam at 90° with respect to the flow, so that the remaining beam can perform a velocity measurement with known Doppler angle. In this paper it is shown how this special beam configuration proves particularly suitable for volume flow measurements. While the transverse beam performs a diameter measurement with optimal orientation, the velocity distribution along the second beam is measured through multigate spectral analysis. The method has been coded on a research system. In-vitro experiments produced a bias less then 7% with a coefficient of variability (CV) less then 5%. In preliminary tests on 3 volunteers CVs within 10% were obtained.
Volumetric Blood Flow Assessment through Multigate Spectral Doppler / S. Ricci; M. Cinthio; L. Francalanci; P. Tortoli. - ELETTRONICO. - (2009), pp. 570-573. (Intervento presentato al convegno Ultrasonics Symposium 2009 tenutosi a Roma nel Settembre) [10.1109/ULTSYM.2009.5442066].
Volumetric Blood Flow Assessment through Multigate Spectral Doppler
RICCI, STEFANO;FRANCALANCI, LORENZO;TORTOLI, PIERO
2009
Abstract
Volumetric blood flow measurements require the assessment of both the velocity distribution and the cross-sectional area of the vessel. Unfortunately several difficulties hamper such a measurement in standard approaches. A new dual beam method has been recently introduced in which the Doppler spectral symmetry is exploited to finely orientating the first beam at 90° with respect to the flow, so that the remaining beam can perform a velocity measurement with known Doppler angle. In this paper it is shown how this special beam configuration proves particularly suitable for volume flow measurements. While the transverse beam performs a diameter measurement with optimal orientation, the velocity distribution along the second beam is measured through multigate spectral analysis. The method has been coded on a research system. In-vitro experiments produced a bias less then 7% with a coefficient of variability (CV) less then 5%. In preliminary tests on 3 volunteers CVs within 10% were obtained.File | Dimensione | Formato | |
---|---|---|---|
getPDF.pdf
Accesso chiuso
Tipologia:
Versione finale referata (Postprint, Accepted manuscript)
Licenza:
Tutti i diritti riservati
Dimensione
968.29 kB
Formato
Adobe PDF
|
968.29 kB | Adobe PDF | Richiedi una copia |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.