Purpose: To describe an alternative reconstruction for bilateral common (CIA) and internal (IIA) iliac artery aneurysms associated with external iliac artery (EIA) occlusion in a patient unfit for open surgery. Case Report: A high-risk 81-year-old man presented with contained rupture of a left CIA aneurysm in the presence of bilateral CIA and NA aneurysms associated with complete occlusion of the left. EIA and normal patency of both common femoral arteries. In an emergent procedure, the left EIA was recanalized subintimally, and the right IIA was embolized with a 14-mm Amplatzer Plug. The main body of a standard Excluder endograft was deployed just distal to the origin of the left renal artery, and the ipsilateral leg was extended into the proximal right EIA. On the contralateral side, a short 10-mm-diameter limb was inserted through a 12-F sheath and deployed in the CIA, proximal to the iliac bifurcation. Via a percutaneous left brachial artery access, 3 covered stents (9x59 mm, 10x59 mm, 10x59 mm) were deployed from the distal HA to the endograft contralateral limb. A right-to-left femorofemoral crossover bypass graft concluded the operation. The patient was discharged on the 5th postoperative day without complications; follow-up imaging at 6 months showed patency of the stent-graft and crossover bypass, with complete exclusion of the aneurysms and no evidence of endoleak. Conclusion: This case demonstrates an effective solution for complex aortoiliac lesions using commercially available devices, underlining how an accurate knowledge of alternative endovascular techniques and materials is crucial in the management of complex cases
Alternative hybrid reconstruction for bilateral common and internal iliac artery aneurysms associated with external iliac artery occlusion / Pratesi G; Pulli R; Fargion A; Marek J; Troisi N; Dorigo W; Innocenti AA; Pratesi C.. - In: JOURNAL OF ENDOVASCULAR THERAPY. - ISSN 1526-6028. - STAMPA. - 16 (5):(2009), pp. 638-641.
Alternative hybrid reconstruction for bilateral common and internal iliac artery aneurysms associated with external iliac artery occlusion.
PULLI, RAFFAELE;FARGION, AARON THOMAS;TROISI, NICOLA;DORIGO, WALTER;PRATESI, CARLO
2009
Abstract
Purpose: To describe an alternative reconstruction for bilateral common (CIA) and internal (IIA) iliac artery aneurysms associated with external iliac artery (EIA) occlusion in a patient unfit for open surgery. Case Report: A high-risk 81-year-old man presented with contained rupture of a left CIA aneurysm in the presence of bilateral CIA and NA aneurysms associated with complete occlusion of the left. EIA and normal patency of both common femoral arteries. In an emergent procedure, the left EIA was recanalized subintimally, and the right IIA was embolized with a 14-mm Amplatzer Plug. The main body of a standard Excluder endograft was deployed just distal to the origin of the left renal artery, and the ipsilateral leg was extended into the proximal right EIA. On the contralateral side, a short 10-mm-diameter limb was inserted through a 12-F sheath and deployed in the CIA, proximal to the iliac bifurcation. Via a percutaneous left brachial artery access, 3 covered stents (9x59 mm, 10x59 mm, 10x59 mm) were deployed from the distal HA to the endograft contralateral limb. A right-to-left femorofemoral crossover bypass graft concluded the operation. The patient was discharged on the 5th postoperative day without complications; follow-up imaging at 6 months showed patency of the stent-graft and crossover bypass, with complete exclusion of the aneurysms and no evidence of endoleak. Conclusion: This case demonstrates an effective solution for complex aortoiliac lesions using commercially available devices, underlining how an accurate knowledge of alternative endovascular techniques and materials is crucial in the management of complex casesFile | Dimensione | Formato | |
---|---|---|---|
case report aneur iliaco JET.pdf
Accesso chiuso
Tipologia:
Versione finale referata (Postprint, Accepted manuscript)
Licenza:
Tutti i diritti riservati
Dimensione
397.15 kB
Formato
Adobe PDF
|
397.15 kB | Adobe PDF | Richiedi una copia |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.