Large double-sided readout silicon strip detectors have been fabricated for the Aleph minivertex. We have tested them with a β-source and have observed charge collection and capacitive charge division both on the junction side and on the ohmic side. A charge correlation has been observed between the two faces and can be used to reduce ambiguities in the case of two particles crossing the same wafer.

Double-sided readout silicon strip detectors for the aleph minivertex / G. Batignani;F. Bosi;L. Bosisio;A. Conti;E. Focardi;F. Forti;M.A. Giorgi;G. Parrini;E. Scarlini;P. Tempesta;G. Tonelli;G. Triggiani. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - ELETTRONICO. - 277:(1989), pp. 147-153. [10.1016/0168-9002(89)90546-9]

Double-sided readout silicon strip detectors for the aleph minivertex

FOCARDI, ETTORE;PARRINI, GIULIANO;SCARLINI, ENRICO;
1989

Abstract

Large double-sided readout silicon strip detectors have been fabricated for the Aleph minivertex. We have tested them with a β-source and have observed charge collection and capacitive charge division both on the junction side and on the ohmic side. A charge correlation has been observed between the two faces and can be used to reduce ambiguities in the case of two particles crossing the same wafer.
1989
277
147
153
G. Batignani;F. Bosi;L. Bosisio;A. Conti;E. Focardi;F. Forti;M.A. Giorgi;G. Parrini;E. Scarlini;P. Tempesta;G. Tonelli;G. Triggiani...espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/627001
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 56
  • ???jsp.display-item.citation.isi??? 55
social impact